Server component identification
23
System LED and
Color
Internal Health
LED Color
Status
Fan (amber)
Amber (flashing)
Redundant fan has failed.
Red (flashing)
The minimum fan requirements are not being met. One
or more fans have failed or are missing.
SCSI configuration
error (amber) *
Red (flashing)
SCSI cabling or terminator configuration is incorrect for
SCSI backplane.
*This feature applies only to SCSI models.
SCSI backplane LEDs
Item LED
Description
Status
1
SCSI configuration
On = Simplex
Off = Duplex
2
SCSI configuration error
On = SCSI cabling or terminator
configuration is incorrect
Off = SCSI cabling or terminator
configuration is correct