S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
39
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(2)
OL-25090-02
Caveats
•
CSCtr52721
Symptom
: On the 48-port 8-Gbps Advanced Fibre Channel switching module (DSX9248-256K9),
port monitoring and alarms for Tx and Rx traffic can get disabled under some conditions for ports
that have their speed set as “switchport speed auto.”
Workaround
: This issue is resolved.
•
CSCts21095
Symptom
: Lower than expected performance occurred when a Qlogic HBA was connected to a
Cisco MDS 9000 switch and a port was configured in F-mode. The switch responded to a Get Port
Speed Capabilities (GPSC) request with incorrect values for both Port Speed Capabilities and Port
Operating Speed:
–
The Port Speed Capabilities was not set to any value.
–
For a port speed of 1 Gbps, the switch responded with Port Operating Speed of 10 Gbps.
–
For a port speed of 2 Gbps, the switch responded with Port Operating Speed 4 Gbps.
–
For a port speed of 4 Gbps, the switch responded with Port Operating Speed 2Gbps.
–
For a port speed of 8 Gbps, the switch responded with Port Operating Speed, speed not
established
–
For a port speed of10 Gbps, the switch responded with Port Operating Speed 1Gbps
Workaround
: This issue is resolved.
•
CSCtx32991
Symptom
: A temperature sensor alarm might occur with sensor 1 or sensor 2 on the 32-port 8-Gbps
Advanced Fibre Channel Switching Module (DS-X9232-256K9). The following error appears:
%PLATFORM-4-MOD_TEMPFAIL:
The output of the
show environment temperature
command shows that the sensor status is failure.
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 Outlet1 n/a n/a n/a Failure
1 Outlet2 n/a n/a n/a Failure
...
Workaround
: This issue is resolved.
•
CSCtn68418
Symptom
: When you try to save a configuration, you might see the following message:
switch#
copy run start
[########################################] 100%
Configuration update aborted: request was aborted
%DAEMON-3-SYSTEM_MSG: ntp:can't open /mnt/pss/ntp.drift.TEMP: No space left on device
- ntpd[xxxx]
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR ALERT RECOVERED
`show system internal flash` output will display /isan as 100% full.
Mount-on 1K-blocks Used Available Use% Filesystem
/ 204800 54624 150176 27 /dev/root
/proc 0 0 0 0 proc
/isan 409600 409576 24 100 none