Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(2)
OL-25090-02
Caveats
5 2 sb_part.0.0.0 12350000 Jan 12 11:54
5 2 sb_part.0.0.1 12350100 Jan 12 11:54
5 2 sb_part.0.0.2 12350200 Jan 12 11:54
This symptom might be seen because after packet decompression of a corrupted packet, the source
of the packet is unknown and FCIP is unable to retrieve the FCIP header, SOF, or EOF. FCIP returns
SYNC LOSS, which flaps the FCIP link.
Workaround
: This issue is resolved.
•
CSCtq35662
Symptom
: Due to an ASIC issue, there are no credits reserved for high priority traffic on the 48-port
8-Gbps Advance Fibre Channel switching module. As a result, for a long-distance connection, port
credits may go to zero, which can cause the fabric merge to fail. This issue might be seen when a
fabric merge fails for a long-distance ISL.
Workaround
: This issue is resolved.
•
CSCtq42878
Symptom
: When you configure dynamic port VSAN membership (DPVM) using device alias and
then remove the alias before clearing the DPVM configuration, the node NWWN configuration will
not take effect for the device when you enter the
activate force
command. This issue might be seen
when you configure a device in DPVM using device alias, and then remove the device alias mapping
for that device. If you configure the same device in DPVM using NWWN and enter the
activate
force
command, the device is not logged out and does not log in again to the NWWN configured
VSAN.
Workaround
: This issue is resolved.
•
CSCtr04426
Symptom
: On a Cisco MDS 9000 switch, the tech support CLI for some FCoE components, such
as VLAN_MGR and ASSOC_MGR, may appear as part of the
show tech-support
command output,
even though the FCoE plugin is not loaded.
Workaround
: This issue is resolved.
•
CSCtr42322
Symptom
: When you have IVR zone member with devices attached to the 8-port FCoE module
(DS-X9708-K9) or the 48-port 8-Gbps Advanced Fibre Channel switching module
(DSX9248-256K9), and you perform certain actions such as a module reload, VSAN suspend, or
device port flapping, the device does not get exported and the FC ID rewrite entries are missing. This
issue might be seen when there are IVR zone members with devices attached to the 8-port FCoE
module or the 48-port 8-Gbps Advanced Fibre Channel switching module and you do any of the
following:
–
Flap the device port on the 8-port FCoE module or the 48-port 8-Gbps Advanced Fibre Channel
switching
–
Reload the module with the device attached
–
Suspend or no suspend the VSAN where the device is a member
Workaround
: This issue is resolved.
•
CSCtr44412
Symptom
: Configuring a static area FC ID with an area that was used for a single static FC ID
configuration will fail. This issue impacts only the area where a single static entry is added and
removed later, particularly if the area will still be available for a single FC ID configuration.
Workaround
: This issue is resolved.