Caveats
This symptom might be seen when a switch is downgraded from Cisco NX-OS Release 5.1(x) or
Release 5.2(1) to NX-OS Release 4.2(x), and there is no Call Home configuration in the startup
configuration.
Workaround
: This issue is resolved.
•
CSCtt02102
Symptom
: The feature manager is not responsive and goes into a loop. As a result, interfaces cannot
be allocated to the storage VDC on a switch that is running the NPE image.
Workaround
: This issue is resolved.
•
CSCtw60186
Symptom
: A Cisco MDS 9000 switch that is configured for FICON Tape Acceleration (FTA) might
not correctly clear an existing FICON exchange if the proper sequence of Fibre Channel frames that
are needed to close the exchange are not seen. This situation can lead to a collision for a scheduled
slot and can cause the MSM-18/4 module to reload unexpectedly.
This symptom might be seen when a host or control unit does not properly close out an exchange
because of some error condition.
Workaround
: This issue is resolved.
•
CSCtw75689
Symptom
: Following a software upgrade on a switch with a single supervisor, active Port Monitor
policies disappear. This symptom occurs only on a single-supervisor switch.
Workaround
: This issue is resolved.
•
CSCtw95270
Symptom
: A Cisco MDS 9000 switch that is configured for FICON Tape Acceleration (FTA) might
not account correctly for an acknowledged exchange that was previously accelerated. This situation
can cause the MSM-18/4 module to reload unexpectedly.
This symptom might be seen during times when the host is busy and it stacks the status from the
tape drive (control unit) until later when it requests status with a “request-status” message.
Workaround
: This issue is resolved.
•
CSCtn93151
Symptom
: Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4), DS-X9304-18K9, might
fail and have the following logs in the syslog:
2012 Jan 12 11:54:22 rmdsrdc4-sl-01 %IPS_SB_MGR-SLOT5-2-PORT_SOFTWARE_FAILURE: Port
software
failure, module 5 port 2
2012 Jan 12 11:54:22 rmdsrdc4-sl-01 %IPS_SB_MGR-SLOT5-2-PORT_SOFTWARE_FAILURE: Port
software
failure, module 5 port 3
2012 Jan 12 11:54:22 rmdsrdc4-sl-01 %IPS_SB_MGR-SLOT5-2-PORT_SOFTWARE_FAILURE: Port
software
failure, module 5 port 4
2012 Jan 12 11:54:22 rmdsrdc4-sl-01 %MODULE-4-MOD_WARNING: Module 5 (serial:
JAE124605F2)
reported warning on ports 5/19-5/34 (Fibre Channel Virtual) due to Skyline ni module
experienced an error in device 60 (device error 0xc3c0067b)
The failure also generates core dumps :
switch#
show cores
Module-num Instance-num Process-name PID Core-create-time
---------- ------------ ------------ --- ----------------