T
ests
and
A
djustments
Menu
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Select
Self-Test
:
Allows
you
to
select
a
diagnostic
self-test.
T
ests
may
be
selected
by
entering
the
number
of
the
test
with
the
keypad,
or
using
the
front-panel
knob
or
4
*
5 /4
+
5
keys
to
scroll
through
the
list
of
tests
.
The
number
,
description,
and
test
status
of
the
currently
selected
test
are
shown.
P
ossible
test
status
notations
are:
\P
ASSED
,"
\F
AILED
,"
and
\NOT
DONE."
See
\Self-tests"
for
a
listing
of
all
the
tests
and
their
descriptions
.
If
any
test
fails
,
refer
to
the
\Troubleshooting
and
Block
Diagrams"
chapter
.
Some
tests
are
run
only
during
power-up
and
the
results
of
these
tests
will
be
displayed
when
the
test
is
selected.
However
,
these
tests
cannot
be
executed
from
this
menu.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Select
Adjustment
:
Allows
you
to
select
an
adjustment.
A
djustments
are
listed
in
numerical
order
.
The
adjustments
can
be
performed
in
numerical
order
,
but
a
more
convenient
order
is
shown
in
the
\A
djustments"
chapter
.
T
o
select
an
adjustment,
use
the
numeric
keypad
to
enter
the
adjustment
number
,
or
use
the
front-panel
knob
or
up/down
arrow
keys
to
scroll
through
the
list.
The
number
,
description,
and
test
status
of
the
currently
selected
test
are
shown.
P
ossible
test
status
notations
are:
\P
ASSED
,"
\F
AILED"
and
\NOT
DONE."
See
\A
djustments"
for
a
listing
of
the
adjustments
and
their
descriptions
.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Execute
Test
:
Executes
the
selected
test
or
adjustment.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Stop
Test
:
This
stops
any
test
that
is
currently
running.
Select
Self-T
est
Menu
Internal
tests
can
be
used
in
troubleshooting
the
analyzer
.
Only
the
ones
marked
with
an
asterisk
(*)
in
T
able
5-1
are
executed
during
the
power-up
sequence
.
The
pass/fail
status
of
these
tests
can
be
checked
by
scrolling
through
the
list
of
self-tests
.
Also
,
if
any
test
fails
during
power-up
,
the
number
of
the
rst
test
to
fail
will
be
displayed
on
the
\T
est
Results"
LED
which
is
visible
through
an
opening
in
the
analyzer's
rear
panel.
Note
There
are
two
LEDs
to
the
left
of
the
seven-segment
\T
est
Results"
LED
on
the
rear
panel
of
the
analyzer
.
The
red
LED
is
on
for
self-tests
1
through
9,
and
the
green
LED
is
on
for
tests
10
through
19.
If
all
tests
pass
,
the
green
LED
will
be
on,
and
the
red
LED
and
the
seven-segment
LED
will
be
o.
Service
Related
Menus
5-3
Summary of Contents for 87114B
Page 7: ......
Page 19: ...Absolute Power Accuracy broadband Dynamic Accuracy narrowband 1 4 Performance T ests ...
Page 39: ......
Page 73: ......
Page 89: ......
Page 115: ......
Page 116: ......
Page 118: ...Figure 5 1 The Service Key Menus 5 2 Service Related Menus ...
Page 132: ......
Page 162: ......
Page 164: ......
Page 170: ......