![HP 84125C User Manual Download Page 70](http://html.mh-extra.com/html/hp/84125c/84125c_user-manual_161498070.webp)
3.
Press
4
SP
AN
5
10
4
MHz
5 ,
or
a
frequency
span
that
will
make
a
calibrated
measurement.
4.
Press
4
MKR
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SIG
TRK
ON
OFF
with
OFF
underlined.
5.
Press
4
AMPLITUDE
5 ,
NNNNNNNNNNNNNNNNNNNNNNN
Ref
Lvl
and
adjust
the
reference
level
to
bring
the
signal
near
the
top
of
the
display
.
6.
Press
4
MODULE
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
USER
KEYS
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SELECT
LINEAR
to
select
a
linear
amplitude
scale
.
Note
Amplitude
correction
is
turned
o
in
Linear
mode
.
The
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
dB V/m
softkey
must
be
used
to
make
a
dBV/m
reading
at
a
single
point.
Notice
that
the
limit
line
is
removed
when
in
Linear
mode
.
In
Linear
mode
,
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MKR
LIM
ON
OFF
softkey
replaces
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
LIM
LINE
ON
OFF
softkey
.
When
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MKR
LIM
ON
OFF
is
ON,
a
limit
fail
message
will
be
displayed
if
the
signal
(using
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
dB V/m
or
any
of
the
corresponding
peak
search
keys)
exceeds
the
limit
set.
7.
Press
4
AMPLITUDE
5 ,
NNNNNNNNNNNNNNNNNNNNNNN
Ref
Lvl
and
adjust
the
reference
level
to
bring
the
signal
near
the
top
of
the
display
.
8.
Press
4
BW
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
VIDEO
BW
AUTO
MAN
with
MAN
underlined.
Use
the
down
arrow
key
to
reduce
the
video
bandwidth.
Continue
to
reduce
the
video
bandwidth
until
the
trace
becomes
smoothed
and
ceases
to
change
.
A
veraging
occurs
when
the
video
bandwidth
is
smaller
than
the
lowest
pulse
repetition
frequency
(PRF)
of
the
signal
being
measured.
Note
If
the
signal
of
interest
is
greater
than
2.9
GHz,
perform
a
preselector
peak
by
pressing,
4
AMPLITUDE
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MORE
1
OF
3
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MORE
2
0F
3
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
PRESEL
AUTO
PK
.
9.
Press
4
MODULE
5 ,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
USER
KEYS
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MARKER
dB V/m
to
activate
the
marker
.
10.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
HIGHEST
PEAK
,
or
any
of
the
other
marker
softkeys
,
to
place
the
marker
on
the
emission.
If
the
marker
value
exceeds
the
limit
then
the
message
,
\LIMIT
F
AILED"
will
appear
above
the
Corrected
Linear
Marker
V
alue
.
11.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
ADD
TO
MKR
LIST
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SAVE
MKR
#2
to
add
the
signal
to
the
marker
list.
Tip
T
o
view
the
signals
in
the
marker
list,
press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Main
Menu
,
NNNNNNNNNNNNNN
MORE
,
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
VIEW
MKR
LIST
.
12.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
Main
Menu
,
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
SELECT
LOG
to
return
to
a
logarithmic
amplitude
scale
.
Making
Measurements
6-5
Summary of Contents for 84125C
Page 7: ......
Page 13: ......
Page 19: ...Figure 2 1 HP 84125C System Dimensions 2 4 Speci cations and Characteristics ...
Page 45: ......
Page 55: ...DLP Softkey Menu Figure 5 1 DLP softkey menu 5 2 System Interface ...
Page 65: ......
Page 71: ......
Page 85: ......
Page 91: ...8 6 Customer Support ...
Page 97: ......