7-9
Adjustments/Calibrations
BAIL CALIBRATION
In this procedure, the ‘up’ position of the bail assembly is calibrated. A value is stored in the
EEROM when the procedure is completed.
Perform the bail calibration whenever the:
Bail Calibration is accessible through the ª
Service Tests
º menu. To perform the bail
calibration, do the following:
1. Press
Enter
at the ª
Status
º display.
2. Use the arrow buttons to scroll to the ª
Utilities
º main menu. Press
Enter
.
3. Simultaneously press the
Enter
and the
Up Arrow
buttons to access the
ªService
Test
º submenu.
4. Scroll to the ª
Bail Calib
º submenu. Press
Enter
.
5. The bail will raise.
6. Press the
Up Arrow
button. Each time the button is pressed, the bail will raise
up slightly.
7. Press the
Up Arrow
button until the bail makes a slight falling motion. This is the
correct ‘up’ position.
8. Press
Enter
to store the calibration value in EEROM.