HP 5130 EI Switch Series 

Installation Guide 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part number: 5998-5492c 
Document version: 6W102-20150817 

 

 

 

Summary of Contents for 5130 EI Switch Series

Page 1: ...HP 5130 EI Switch Series Installation Guide Part number 5998 5492c Document version 6W102 20150817 ...

Page 2: ...IS MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material The only warranties for HP products and services are set forth in the express warranty statements accom...

Page 3: ...supply 15 Connecting the power cord 16 Connecting the switch to an AC power source 17 Connecting the switch to a 48 VDC power source 18 Connecting the switch to an RPS 19 Verifying the installation 19 Accessing the switch for the first time 21 Setting up the configuration environment 21 Connecting the console cable 21 Setting terminal parameters 22 Powering on the switch 22 Setting up an IRF fabri...

Page 4: ... HP 5130 48G PoE 2SFP 2XGT 370W EI 39 HP 5130 24G SFP 4SFP EI 39 Technical specifications 40 Appendix B FRUs 44 Appendix C Ports and LEDs 45 Ports 45 Console port 45 10 100 1000Base T autosensing Ethernet port 45 1 10GBase T autosensing Ethernet port 45 100 1000Base X SFP port 46 SFP port 48 Combo interface 49 LEDs 49 System status LED 49 Power supply status LED 50 RPS status LED 50 Port mode LED ...

Page 5: ...I BR JG977A HP 5130 24G PoE 4SFP 370W EI Brazil Switch HP 5130 24G PoE 4SFP 370W EI BR JG978A HP 5130 48G PoE 4SFP 370W EI Brazil Switch HP 5130 48G PoE 4SFP 370W EI BR Power supplies applies only to the JG933A switch JD362A PSR150 A1 N A JD366A PSR150 D1 N A For regulatory identification purposes the HP 5130 24G 4SFP EI HP 5130 24G SFP 4SFP EI HP 5130 48G 4SFP EI HP 5130 24G PoE 4SFP 370W EI HP 5...

Page 6: ... cleaning the switch remove all power cords from the switch Do not clean the switch with wet cloth or liquid Do not place the switch near water or in a damp environment Prevent water or moisture from entering the switch chassis Do not place the switch on an unstable case or desk Ensure good ventilation at the installation site and keep the air inlet and outlet vents of the switch free of obstructi...

Page 7: ...sis views and technical specifications Cleanliness Dust buildup on the chassis might result in electrostatic adsorption which causes poor contact of metal components and contact points especially when indoor relative humidity is low In the worst case electrostatic adsorption can cause communication failure Table 1 Dust concentration limit in the equipment room Substance Concentration limit particl...

Page 8: ...es indoors Laser safety WARNING Do not stare into any fiber port when the switch has power The laser light emitted from the optical fiber might hurt your eyes The HP 5130 EI switches are Class 1 laser devices Installation tools Flat blade screwdriver Phillips screwdriver ESD wrist strap All these installation tools are user supplied Installation accessories Table 3 Installation accessories Product...

Page 9: ...ounding cable 1 HP 5130 24G 4SFP EI HP 5130 24G SFP 4SFP EI HP 5130 48G 4SFP EI HP 5130 24G 2SFP 2XGT EI HP 5130 48G 2SFP 2XGT EI HP 5130 24G 4SFP EI BR HP 5130 48G 4SFP EI BR 5184 6729 Grounding cable 1 HP 5130 24G PoE 4SFP 370W EI HP 5130 48G PoE 4SFP 370W EI HP 5130 24G PoE 2SFP 2XGT 370W EI HP 5130 48G PoE 2SFP 2XGT 370W EI HP 5130 24G PoE 4SFP 370W EI BR HP 5130 48G PoE 4SFP 370W EI BR 5185 9...

Page 10: ... 1 Hardware installation flow Installing the switch in a 19 inch rack Mounting brackets Table 4 describes the mounting brackets provided with the switch Start Install the switch Connect the grounding cable Connect the power cords Verify the installation Turn on the circuit breaker Operating correctly Turn off the circuit breaker Troubleshoot the switch No End Has power supply slots Yes Select and ...

Page 11: ...SFP 2XGT 370W EI HP 5130 24G PoE 4SFP 370W EI BR HP 5130 48G PoE 4SFP 370W EI BR One pair of 1U four hole mounting brackets See Figure 3 Figure 2 1U two hole mounting bracket 1 Screw hole for attaching the bracket to the switch 2 Screw hole for attaching the bracket to the rack post Figure 3 1U four hole mounting bracket 1 Screw hole for attaching the bracket to the switch 2 Screw hole for attachi...

Page 12: ...n and one rear mounting position near the power supplies To attach the mounting brackets to the switch 1 Determine the mounting position 2 Align one mounting bracket with the screw holes at the mounting position Use M4 screws provided with the switch to attach the mounting bracket to the chassis 3 Repeat step 2 to attach the other mounting bracket to the chassis Figure 4 Attaching a two hole mount...

Page 13: ...ake sure it makes good skin contact and is reliably grounded 2 Verify that the mounting brackets have been securely attached to the switch chassis 3 Install cage nuts in the mounting holes in the rack posts 4 One person holds the switch chassis and aligns the mounting brackets with the mounting holes in the rack posts and the other person attaches the mounting brackets with screws user supplied to...

Page 14: ...sis for heat dissipation Do not place heavy objects on the switch If a standard 19 inch rack is not available you can place you switch on a workbench To mount the switch on a workbench 1 Verify that the workbench is sturdy and reliably grounded 2 Place the switch with bottom up and clean the round holes in the chassis bottom with dry cloth 3 Attach the rubber feet to the four round holes in the ch...

Page 15: ...with a grounding strip Grounding the switch with a grounding conductor buried in the earth ground Grounding the switch by using the PE wire of the AC power cord NOTE The power and grounding terminals in this section are for illustration only Grounding the switch with a grounding strip WARNING Connect the grounding cable to the grounding system in the equipment room Do not connect it to a fire main...

Page 16: ...ounding cable to a length according to the distance between the switch and the grounding strip b Peel 20 mm 0 79 in of insulation sheath by using a wire stripper c Use the needle nose pliers to bend the bare wire d Hook the grounding cable to the post on the grounding strip and use the hex nut to secure the cable to the post Figure 14 Connecting the grounding cable to a grounding strip 1 Grounding...

Page 17: ...nding the switch by burying the grounding conductor into the earth ground 1 Grounding screw 2 Grounding cable 3 Earth 4 Joint 5 Grounding conductor 6 Chassis rear panel Grounding the switch by using the PE wire of the AC power cord If the installation site has no grounding strips or earth ground ground an AC powered switch through the PE wire of the power cord Make sure the following requirements ...

Page 18: ...FP 4SFP EI switch provides two power supply slots and comes with power supply slot 1 empty and a filler panel in power supply slot 2 You can install one power supply or two power supplies for redundancy For information about power supplies available for the HP 5130 24G SFP 4SFP EI switch see Appendix B FRUs When two power supplies are installed you can hot swap a power supply To avoid device damag...

Page 19: ...To prevent damage to the power supply and the connector on the switch backplane insert the power supply gently If you encounter a hard resistance or the power supply tilts while inserting the power supply pull out the power supply realign it with the slot and then insert it again 5 Fasten the captive screws on the power supply with a Phillips screwdriver to secure the power supply in the chassis S...

Page 20: ...rd connection procedures at a glance Switch model Available power source Connection procedure reference HP 5130 24G 4SFP EI HP 5130 24G 2SFP 2XGT EI HP 5130 24G 4SFP EI BR AC power source Connecting the switch to an AC power source HP 5130 48G 4SFP EI HP 5130 24G SFP 4SFP EI HP 5130 48G 2SFP 2XGT EI HP 5130 48G 4SFP EI BR AC power source Connecting the switch to an AC power source 48 V DC power so...

Page 21: ... supply supports 48 V DC power input and RPS power input Connecting the switch to an AC power source Securing the AC power cord for a hot swappable AC power supply 1 Insert the cable tie through the hole in the power supply handle 2 Use the cable tie to secure the AC power cord to the power supply handle Figure 21 Securing the AC power cord for a hot swappable AC power supply Securing the AC power...

Page 22: ...nect the switch to a 48 VDC power source 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Correctly orient the plug at one end of the cable with the power receptacle on the power supply and insert the plug into the power receptacle See callout 1 in Figure 24 If you cannot insert the plug into the receptacle re orient the plug rather than use excessive f...

Page 23: ...callout 1 in Figure 24 If you cannot insert the plug into the receptacle re orient the plug rather than use excessive force to push it in 2 Tighten the screws on the plug with a flat blade screwdriver to secure the plug in the RPS receptacle See callout 2 in Figure 24 3 Connect the other end of the power cord to the RPS Figure 25 Connecting an RPS cord to an HP 5130 48G 4SFP EI switch Verifying th...

Page 24: ...wer source is used The power cords are correctly connected All the interface cables are cabled indoors If any cable is routed outdoors verify that the socket strip with lightning protection and lightning arresters for network ports have been correctly connected ...

Page 25: ... 26 Connecting the console port to a terminal Connecting the console cable A console cable is an 8 core shielded cable with a crimped RJ 45 connector at one end for connecting to the console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on the configuration terminal Figure 27 Console cable Table 6 Console cable pinouts RJ 45 Signal DB 9 Signal 1 ...

Page 26: ...ur configuration terminal For more information about the terminal emulator programs see the user guides for these programs The following are the required terminal settings Bits per second 9 600 Data bits 8 Stop bits 1 Parity None Flow control None Powering on the switch Before powering on the switch verify that the following conditions are met The power cord is correctly connected The input power ...

Page 27: ...up completes you can access the CLI to configure the switch For more information about the configuration commands and CLI see HP 5130 EI Switch Series Configuration Guides and HP 5130 EI Switch Series Command References ...

Page 28: ... availability scalability and manageability IRF fabric setup flowchart Figure 28 IRF fabric setup flowchart To set up an IRF fabric Start Plan IRF fabric setup Install IRF member switches Connect the grounding cables and power cords Power on the switches Configure basic IRF settings Connect the physical IRF ports Subordinate switches reboot and the IRF fabric is automatically established End ...

Page 29: ...ion describes issues that an IRF fabric setup plan must cover Planning IRF fabric size and the installation site Choose switch models and identify the number of required IRF member switches depending on the user density and upstream bandwidth requirements The switching capacity of an IRF fabric equals the total switching capacities of all member switches An HP 5130 IRF fabric can have a maximum of...

Page 30: ...IRF port 2 To use an IRF port you must bind at least one physical port to it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch The HP 5130 EI switches can provide 10 GE IRF connections through 1 10 GE Ethernet ports or SFP ports and you can bind several 1 10 GE Ethernet ports o...

Page 31: ... one another choose the SFP transceiver modules with optical fibers If the IRF member switches are all in one equipment room choose twisted pair cables or SFP DAC cables HP recommends that you use ring topology to connect the switches The following describes cabling schemes in ring topology Connecting the IRF member switches in one rack Use SFP DAC cables to connect the IRF member switches 9 switc...

Page 32: ...tion You can install IRF member switches in different racks side by side to deploy a top of rack ToR solution Figure 33 shows an example for connecting 9 top of rack IRF member switches by using SFP transceiver modules and optical fibers The topology is the same as Figure 32 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 ...

Page 33: ...ical IRF ports Use twisted pair cables SFP DAC cables or SFP transceiver modules and fibers to connect the IRF member switches as planned Wear an ESD wrist strap when you connect twisted pair cables SFP DAC cables or SFP transceiver modules and fibers For how to connect them see SFP SFP XFP Transceiver Modules Installation Guide Verifying the IRF fabric setup To verify the basic functionality of t...

Page 34: ...ffect at a reboot display irf configuration Display IRF fabric topology information display irf topology NOTE To avoid IP address collision and network problems configure at least one multi active detection MAD mechanism to detect the presence of multiple identical IRF fabrics and handle collisions For more information about MAD detection see HP 5130 EI Switch Series IRF Configuration Guide ...

Page 35: ...atus LED RPS Steady green The AC input is normal and the RPS is in position or working normally Steady yellow RPS power input is normal but AC input has failed or AC input is not connected Off No RPS is connected AC input If the system status LED is off an AC input failure has occurred To resolve the problem 1 Verify that the AC power cord is securely connected to the switch and the AC input power...

Page 36: ...status LED is steady yellow an AC input failure has occurred To resolve the problem a Verify that the AC power cord is securely connected to the switch and the AC input power receptacle on the switch and the connected AC power outlet are in good condition b Verify that the AC power source is operating correctly c If the problem persists contact HP Support If the system status LED is on but the RPS...

Page 37: ...ly 4 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None 5 Verify that the console cable is not faulty 6 If the problem persists contact HP support Garbled display on the configuration terminal The configuration terminal displays garbled text To resolve the problem 1 Verify that the following settings are configure...

Page 38: ...I HP 5130 24G 4SFP EI BR Figure 34 Front panel 1 10 100 1000Base T autosensing Ethernet port 2 SFP port 3 Console port 4 10 100 1000Base T autosensing Ethernet port LED 5 SFP port LED 6 System status LED SYS Figure 35 Rear panel 1 AC input power receptacle 2 Grounding screw 1 2 3 4 5 6 1 2 ...

Page 39: ...rt LED 8 System status LED SYS 9 RPS status LED RPS Figure 37 Rear panel 1 AC input power receptacle 2 RPS receptacle 3 Grounding screw HP 5130 24G 2SFP 2XGT EI Figure 38 Front panel 1 10 100 1000Base T autosensing Ethernet port 2 SFP port 3 1 10GBase T autosensing Ethernet port 4 Console port 5 10 100 1000Base T autosensing Ethernet port LED 6 SFP port LED 7 System status LED SYS 8 1 10GBase T au...

Page 40: ...ort 3 1 10GBase T autosensing Ethernet port 4 Console port 5 Port LED mode switching button 6 10 100 1000Base T autosensing Ethernet port LED 7 SFP port LED 8 System status LED SYS 9 RPS status LED RPS 10 1 10GBase T autosensing Ethernet port LED 11 Port mode LED Figure 41 Rear panel 1 AC input power receptacle 2 RPS receptacle 3 Grounding screw 1 2 1 3 4 6 2 5 8 9 7 10 11 2 3 1 ...

Page 41: ...LED RPS Figure 43 Rear panel 1 AC input power receptacle 2 RPS receptacle 3 Grounding screw HP 5130 48G PoE 4SFP 370W EI HP 5130 48G PoE 4SFP 370W EI BR Figure 44 Front panel 1 10 100 1000Base T autosensing Ethernet port 2 10 100 1000Base T autosensing Ethernet port LED 3 Console port 4 SFP port 5 Port LED mode switching button 6 Port mode LED 7 System status LED SYS 8 RPS status LED RPS 9 SFP por...

Page 42: ...tosensing Ethernet port 2 10 100 1000Base T autosensing Ethernet port LED 3 SFP port 4 Console port 5 1 10GBase T autosensing Ethernet port 6 System status LED SYS 7 RPS status LED RPS 8 1 10GBase T autosensing Ethernet port LED 9 SFP port LED Figure 47 Rear panel 1 AC input power receptacle 2 RPS receptacle 3 Grounding screw 1 2 3 1 2 3 7 4 5 6 9 8 1 2 3 ...

Page 43: ... 10GBase T autosensing Ethernet port LED 11 SFP port LED Figure 49 Rear panel 1 AC input power receptacle 2 RPS receptacle 3 Grounding screw HP 5130 24G SFP 4SFP EI Figure 50 Front panel 1 100 1000Base X SFP port 2 100 1000Base X SFP port LED 3 10 100 1000Base T autosensing Ethernet port 4 10 100 1000Base T autosensing Ethernet port LED 5 SFP port 6 SFP port LED 7 Console port 8 System status LED ...

Page 44: ...cations Table 9 Technical specifications for non PoE switch models Item HP 5130 24G 4SF P EI HP 5130 24G 4SF P EI BR HP 5130 24G 2 SFP 2XGT EI HP 5130 48G 4SF P EI HP 5130 48G 4SF P EI BR HP 5130 24G SF P 4SFP EI HP 5130 48G 2S FP 2XGT EI Dimensions H W D 43 6 440 160 mm 1 72 17 32 6 30 in 43 6 440 160 mm 1 72 17 32 6 30 in 43 6 440 260 mm 1 72 17 32 10 24 in 43 6 440 360 mm 1 72 17 32 14 17 in 43...

Page 45: ...AC to 240 VAC 50 or 60 Hz Max voltage 90 VAC to 264 VAC 47 to 63 Hz DC power source 48 V DC power source in the equipment room or RPS recommended HP RPS models A RPS800 or A RPS1600 Rated voltage 48 VDC to 60 VDC Max voltage 36 VDC to 72 VDC Minimum power consumption 19 W 20 W AC 38 W DC 38 W AC 30 W DC 38 W AC 36 W DC 36 W Maximum power consumption 26 W 34 W AC 45 W DC 50 W AC 60 W DC 68 W AC 54 ...

Page 46: ... 32 11 81 in 43 6 440 360 mm 1 72 17 32 14 17 in 43 6 440 420 mm 1 72 17 32 16 54 in Weight 6 kg 13 23 lb 8 kg 17 64 lb 8 kg 17 64 lb 7 kg 15 43 lb Console ports 1 1 1 1 10 100 10 00Base T autosensing Ethernet ports 24 24 48 48 1 10GBase T autosensing Ethernet ports 2 N A N A 2 SFP ports 2 4 4 2 Input voltage Rated voltage 100 VAC to 240 VAC 50 or 60 Hz Max voltage 90 VAC to 264 VAC 47 to 63 Hz AC...

Page 47: ... W PoE consumption DC 790 W including 740 W PoE consumption AC 490 W including 370 W PoE consumption DC 890 W including 800 W PoE consumption AC 470 W including 370 W PoE consumption DC 910 W including 800 W PoE consumption Chassis leakage current compliance UL60950 1 EN60950 1 IEC60950 1 GB4943 1 Melting current of power supply fuse AC input 10 A 250 V DC input 25 A 250 V AC input 10 A 250 V DC i...

Page 48: ... supply model Item Specification Remarks PSR150 A1 Rated input voltage 100 VAC to 240 VAC 50 Hz or 60 Hz For more information about the power supplies see HP PSR150 A PSR150 D Power Supplies User Guide Max input voltage 90 VAC to 264 VAC 47 Hz to 63 Hz Max output power 150 W PSR150 D1 Rated input voltage 48 VDC to 60 VDC Max input voltage 36 VDC to 72 VDC Max output power 150 W When two power supp...

Page 49: ...osensing Ethernet port The switch provides 10 100 1000Base T autosensing Ethernet ports Table 13 10 100 1000Base T autosensing Ethernet port specifications Item Specification Connector type RJ 45 Interface attributes 10 100 1000 Mbps half full duplex MDI MDI X autosensing Max transmission distance 100 m 328 08 ft Transmission medium Category 5 or above twisted pair cable Compatible standards IEEE ...

Page 50: ...rame and port 2 on the device to port 3 on the distribution frame If the device connects to two distribution frames connect port 1 on the device to port 1 on distribution frame 1 and port 2 on the device to port 1 on distribution frame 2 Keep the device and twisted pair cables away from the interference source such as a two way radio and a high power variable frequency drive 100 1000Base X SFP por...

Page 51: ... X120 1G SFP LC SX Transceiver 850 LC Multi mode 50 125 500 550 m 1804 46 ft 400 500 m 1640 42 ft Multi mode 62 5 125 200 275 m 902 23 ft 160 220 m 721 78 ft JD119B HP X120 1G SFP LC LX Transceiver 1310 LC Single mode 9 125 N A 10 km 6 21 miles Multi mode 50 125 500 or 400 550 m 1804 46 ft Multi mode 62 5 125 500 550 m 1804 46 ft JD061A HP X125 1G SFP LC LH40 1310nm Transceiver 1310 LC Single mode...

Page 52: ...able 18 in the SFP ports as needed Table 17 SFP transceiver modules available for the SFP ports Product Code HP description Central wavelength nm Connector Fiber diameter µm Modal bandwidth MHz km Max transmission distance JD092B HP X130 10G SFP LC SR Transceiver 850 LC Multi mode 50 125 2000 300 m 984 25 ft 500 82 m 269 03 ft 400 66 m 216 54 ft Multi mode 62 5 125 200 33 m 108 27 ft 160 26 m 85 3...

Page 53: ...vices Transceiver Modules User Guide Figure 52 SFP DAC cable 1 Connector 2 Pull latch Combo interface The HP 5130 24G SFP 4SFP EI switch provides eight combo interfaces A combo interface includes an SFP port and a 10 100 1000Base T autosensing Ethernet port Only one of these two ports can operate at a time LEDs System status LED The system status LED shows the operating status of the switch Table ...

Page 54: ...4SFP 370W EI BR and HP 5130 48G PoE 4SFP 370W EI switches support RPS input and provide an RPS status LED on the front panel to indicate the RPS operating status Table 21 RPS status LED description LED mark Status Description RPS Steady green Both the RPS DC input and the AC input are normal Steady yellow The RPS DC input is normal but the AC input is disconnected or has failed Off The RPS DC inpu...

Page 55: ...nt on the port Flashing yellow not 3 Hz The port is sending or receiving data at 10 100 Mbps Flashing yellow 3 Hz The port has failed POST Off No link is present on the port HP 5130 48G PoE 4SFP 370W EI HP 5130 48G PoE 4SFP 370W EI BR HP 5130 48G PoE 2SFP 2 XGT 370W EI Steady green rate mode Steady green The port is operating at 1000 Mbps and a link is present on the port Flashing green The port i...

Page 56: ...SFP EI HP 5130 24G 4SFP EI BR HP 5130 24G 2SFP 2XGT EI N A Green LED Steady on The port is operating at 1000 Mbps and a link is present on the port Flashing The port is sending or receiving data at 1000 Mbps Off No link is present on the port or the port is not operating at 1000 Mbps Yellow LED Steady on The port is operating at 10 100 Mbps and a link is present on the port Flashing not 3 Hz The p...

Page 57: ... Green LED Steady on The port is supplying PoE correctly Flashing 3 Hz The PD power requirement exceeds the port PoE capacity The port fails to meet the power requirement of the PD because of power insufficiency of the switch Off The port is not supplying PoE power Yellow LED Steady on A non PD device is attached to the port or the port is experiencing a PoE failure Flashing 3 Hz The port has fail...

Page 58: ... port LED Status Description Green LED Steady on The port is operating at 10 Gbps and a link is present on the port Flashing The port is sending or receiving data at 10 Gbps Off No 10 Gbps link is present on the port The port mode LED is operating in PoE mode applicable to the PoE switch models Yellow LED Steady on The port is operating at 1 Gbps and a link is present on the port Flashing not 3 Hz...

Page 59: ...ng at 10 Gbps and a link is present on the port Flashing green The port is sending or receiving data at 10 Gbps Steady yellow A transceiver module is installed in the port The port is operating at 1 Gbps and a link is present on the port Flashing yellow not 3 Hz The port is sending or receiving data at 1 Gbps Flashing yellow 3 Hz The port has failed POST Off No transceiver module is installed in t...

Page 60: ...to the PoE switch models Yellow LED Steady on A transceiver module is installed in the port The port is operating at 1 Gbps and a link is present on the port Flashing not 3 Hz The port is sending or receiving data at 1 Gbps Flashing 3 Hz The port has failed POST Off No transceiver module is installed in the port or no 1 Gbps link is present on the port The port mode LED is operating in PoE mode ap...

Page 61: ...ents in the chassis and fixed fans To maintain good ventilation for the switch consider the ventilation design at the installation site when you plan the installation position for the switch Figure 53 Airflow through the chassis 1 Air inlet side 2 Air outlet side 3 Port side 3 1 2 ...

Page 62: ...ng you will receive email notification of product enhancements new driver versions firmware updates and other product resources Related information Documents To find related documents browse to the Manuals page of the HP Business Support Center website http www hp com support manuals For related documentation navigate to the Networking section and select a networking category For a complete list o...

Page 63: ...parated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field names and menu items are in bold text For example the New User window appears cli...

Page 64: ...nified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a mesh access point Represents omnidirectional signals Represents directional signals Represents a security product such as a firewall UTM multiservice security gateway or load balancing device Represents a security card such as a firewall load balancing NetStream SSL VPN I...

Page 65: ... cabling scheme 27 chassis attaching mounting bracket to switch chassis 7 views 34 cleanliness installation site 3 combo interface 49 configuring IRF basic settings 29 switch 21 troubleshooting configuration terminal problems 33 verify the IRF fabric setup 29 connecting 48 VDC power source 18 AC power source 17 console cable 21 first time switch access 21 IRF member switches in a ToR solution 28 I...

Page 66: ...al display troubleshooting 33 gas installation site 3 grounding EMI prevention 3 grounding conductor buried in the earth ground 13 grounding strip 1 1 switch 1 1 switch through AC power supply PE wire 13 switch with grounding conductor buried in the earth ground 13 switch with grounding strip 1 1 H hardware 10 100 1000 Base T Ethernet port LED technical specifications 51 10 100 1000 Base T Etherne...

Page 67: ...ying member switch physical ports 27 planning 25 planning cabling scheme 27 27 planning connections 26 planning installation site 25 planning member IDs 25 planning size 25 planning topology 26 setting up 24 setup flowchart 24 verify the IRF fabric setup 29 L LED 10 100 1000 Base T Ethernet port 51 100 1000Base X SFP port 54 port mode 50 power supply status 50 RPS status 50 SFP port 55 system stat...

Page 68: ...fying IRF member switch physical ports 27 installing power supply 15 installing switch 6 installing switch on 19 inch rack 6 maintaining the switch 31 mounting switch on workbench 10 planning IRF connections 26 planning IRF fabric installation site 25 planning IRF member IDs 25 planning IRF topology 26 removing power supply 15 securing AC power cord for fixed AC power supply 17 securing AC power c...

Page 69: ...cabling scheme 27 27 planning IRF member IDs 25 ports 45 powering on 22 rack mounting 9 setting configuration environment 21 setting terminal parameters 22 setting up IRF fabric 24 technical specifications 34 troubleshooting 31 troubleshooting the switch 31 verifying 19 inch rack installation 19 workbench mounting switch 10 system administration troubleshooting configuration terminal problems 33 t...

Page 70: ...nal display 33 hot swappable power supply failure 32 no terminal display 33 power supply failure 31 switch 31 V verify the IRF fabric setup 29 verifying IRF fabric setup 29 switch installation 19 inch rack 19 VT100 22 W workbench mounting switch 10 ...