![background image](http://html.mh-extra.com/html/hp/403349-003/403349-003_maintenance-and-service-manual_17564118.webp)
Technician repair removal and replacement procedures 118
9.
Replace the condensation pump and sensors ("
Replacing the condensation pump and sensors
" on
page
49
).
10.
Relocate the power inlet box back into position ("
Relocating the power inlet box back into position
"
on page
95
).
11.
Replace the bottom fan unit ("
Replacing the bottom fan unit
" on page
45
).
12.
Restore water flow to the MCS unit ("
Restoring water flow
" on page
112
).
13.
Complete the operation checklist (on page
111
).
Magnetic valve
The magnetic valve is a component of the water group located at the bottom interior of the MCS unit.
The following tools are required for installation:
•
T-25 Torx driver
•
Phillips screwdriver
•
8-mm Allen wrench
Removing the magnetic valve diaphragm and spring
1.
Power down the MCS unit ("
Powering down the MCS unit
" on page
24
).
2.
Disconnect the main water lines at the quick disconnect couplings.
3.
Remove the bottom fan unit ("
Removing the bottom fan unit
" on page
44
).
4.
Relocate the power inlet box ("
Relocating the power inlet box
" on page
93
).
5.
Remove the air deflector plate ("
Removing the air deflector plate
" on page
33
).