66
[a] POWER SWITCH
1) Disconnect the Tab Terminals and remove the Nut securing the Power Switch.
2) Install the new Switch in the reverse order of the removal procedure.
3) To prevent miswiring, check the terminal numbers and lead wire colors with the
Wiring Label.
[b] FUSE
1) Use a phillips head screwdriver to remove the Fuse Holder Cap and take out the
Fuse.
2) Install the new Fuse in the reverse order of the removal procedure.
[c] FUSE HOLDER
1) Disconnect the Tab Terminal and remove the Nut securing the Fuse Holder.
2) Install the new Fuse Holder in the reverse order of the removal procedure.
[d] CONTROL BOARD
1) Disconnect all the Connectors.
2) Pull the Tab to release the Control Board.
3) Lift off the Control Board.
4) To re
fi
t the Control Board,
fi
t its four corner holes on the positioning lugs inside the
Control Box and secure the Control Board with the Tab.
5) When reconnecting the Connectors, do not push them too hard. The Control Board
may be damaged.
[e] POWER RELAY
1) Disconnect the Tab Terminals, remove the mounting screw, and lift off the Power
Relay from the
fi
t at the bottom.
2) Install the new Relay in the reverse order of the removal procedure.