52
9. WATER-COOLED CONDENSER - KM-151BWH ONLY
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repair or replacement
has been made.
1) Unplug the icemaker or disconnect the power source.
2) Close the water supply line Shout-off Valve.
3) Remove the Louver, Top panel, Rear Panel, Rear Cover and Pipe Cover.
4) Recover the refrigerant and store it in a container, if required by applicable law (see “1.
[b] REFRIGERANT RECOVERY”)
5) Remove the Inlet Nut for the Water Valve.
6) Remove the four bolts securing the body at the front and rear.
Fig. 8