30
[b] KM-101BAH
70/21
115
52
107
49
97
44
80/27
109
50
97
44
87
40
90/32
107
49
88
40
78
35
lbs./day kg./day
100/38
106
48
86
39
69
31
70/21
80/27
90/32
watts
100/38
70/21
47
0.18
39
0.15
36
0.14
80/27
41
0.16
29
0.11
29
0.11
90/32
39
0.15
20
0.08
19
0.07
gal./day m
3
/day
100/38
31
0.12
20
0.08
18
0.07
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
109
7.7
127
8.9
148
10.4
80/27
123
8.6
150
10.6
170
12.0
90/32
127
8.9
170
12.0
191
13.4
PSIG kg/cm
2
G
100/38
130
9.1
175
12.3
210
14.8
70/21
12
0.8
14
1.0
17
1.2
80/27
14
1.0
17
1.2
20
1.4
90/32
14
1.0
19
1.3
23
1.6
PSIG kg/cm
2
G
100/38
15
1.0
20
1.4
26
1.8
2,320 BTU/h [AT 90°F (32°C) / WT 70°F (21°C)]
Note: Pressure data is recorded at 5 minutes into freezing cycle.
The data not in
bold
should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
TOTAL HEAT OF REJECTION FROM CONDENSER
2.0
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
2.0
2.0
2.5
2.0
34
28
29
33
346
354
356
370
32
35
37
41
338
333
337
340
344
330
332
333
26
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (°F/°C)
AMBIENT TEMP.
(°F/°C)
50/10
70/21
90/32
28
28
30
2.1
2.7
2.3
2.5
2.3
2.1
2.6
Summary of Contents for KM-61BAH
Page 16: ...11 ...
Page 30: ...25 2 WIRING DIAGRAM a KM 61BAH ...
Page 31: ...26 b KM 101BAH ...
Page 32: ...27 c KM 151BAH KM 151BWH ...
Page 83: ...78 Water Supply Inlet 1 2 FPT Drain Outlet 3 4 FPT Fig 34 KM 61BAH KM 101BAH KM 151BAH ...