Cleaning Prep:
Close the icemaker water supply line shut-off valve.
Remove the
Front Panel
, move the
power switch
to
OFF
.
Move the
control switch
is
DRAIN
, then move
the
power switch
to
ON
. Replace the
Front Panel
.
Allow the water system to drain completely. Remove the
Front
Panel
, move the
power switch
to
OFF
. Remove the
Top Panel
.
Unplug
the icemaker from the electrical outlet.
Remove all ice
from the ice storage bin and/or dispenser
.
ATTENTION! IF ON DISPENSER,
turn off the dispenser power supply after dispensing
all the leftover ice.
Cleaning:
Remove the
Spout-to-Chute Strap
(includes
Drip Guide
on FS-1500),
then remove the
Spout
.
Dilute Hoshizaki
Scale Away
with
warm water (see Table).
Pour the cleaning solution over the
Extruding
Head
until
the
Evaporator Assembly
and the
Reservoir
are full and the solution
starts to overflow into the drain pan.
Replace
the
Spout
,
Spout-to-Chute Strap
, and
Drip Guide
(if applicable) in
their correct positions.
Allow the icemaker to soak for
10 minutes
before operation.
Cleaning Solution
Scale Away
9.6 fl. oz (0.29 l)
Warm Water
1.6 gal. (6.0 l)
Ice Machine
&^ͲϭϬϬϭD>,Ͳ
&^ͲϭϬϮϮD>,Ͳ
&^ͲϭϱϬϬD>,Ͳ
Sanitizing:
x
Dilute 5.25% chlorine bleach
‡
with warm water
(see Table below)
Sanitizing Solution
Bleach
2.5 fl. oz (0.74 ml)
Warm Water
5 gal. (19 l)
‡
Use bleach without additives.
x
Remove the top panel
x
Remove the spout-to-chute strap
(includes drip guide on FS-1500)
x
Remove the spout,
O-rings,
packing and chute bracket
(FS-1022
and smaller)
or drip guide
(FS-1500)
between spout and chute
x
Pour the sanitizing solution over
the extruding head until the
evaporator
assembly
and
reservoir are full, and it starts to
overflow into the drain pan
x
Remove the proximity switch
from the chute assembly, then
remove the chute assembly
x
Remove the packing at the bottom
of the ice chute. Remove the 3 ties,
the chute insulation, and 2 baffles
x
Remove the plate and the packing
from the top of the ice chute.
Remove the backup bin control
(by
sliding it towards the chute opening &
lifting it off)
x
Disassemble the backup bin
control assembly by removing
the 2 snap pins, shaft, and
actuator
x
Soak the spout, O-rings,
packings, chute bracket
(FS-1022
and smaller)
, drip guide
(FS-1500)
,
chute, baffles, plate, and backup
bin control assembly in the
sanitizing solution for 10 minutes
then wipe them down
Cleaning & Sanitizing
AMMONIA
Cleaners
The icemaker and dispenser must be cleaned & sanitized at least twice a year.
Tech Support: 1.800.233.1940
ϭ
Ϯ
ϯ
R
(
ϱ
)
ϭϱ
ϭϲ
D
ϲ
#51056 | 02.21.2018
ATTENTION!
DO NOT
leave icemaker
unattended when panels are off
To Icemaker
Or Water Filter
SHUT OFF
ϰ
WŽƵƌ^ŽůƵƚŝŽŶŝŶƚŽ
WŽƵƌ^ŽůƵƚŝŽŶ ŝŶƚŽ
džƚƌƵĚŝŶŐ,ĞĂĚ
er
e
ϭϳ
h
n
ϭϴ
1
continued on the back…
ϭϵ
022
ϮϬ
&^ͲϭϬϮϮD>,Ͳ
&^ͲϭϱϬϬD>,Ͳ
&^ͲϭϬϬϭD>,Ͳ
Unplug
Page 30