In bad water conditions, a more thorough cleaning may
be required. Move
control switch
to
OFF
, then turn off
the power supply. Dilute
5 oz. of Scale Away to 1
gallon of warm water.
Remove and clean the float
switch assembly*, water supply tubes, spray tubes,
and spray guides. Rinse thoroughly, then replace in
their correct positions. Turn the power supply back on.
Otherwise, continue to Step
ව
.
*
Remove retainer rod (take care not to bend excessively) from bottom of the
float switch housing & clean all float parts.
Replace all the
Panels,
except the
Front Panel
.
Move the
service switch
to
WASH
, and the
control
switch
to
SERVICE
. Replace the
Front Panel
.
After
30 minutes
, remove the
Front Panel
, move the
service switch
to
DRAIN
. Replace the
Front Panel
.
ATTENTION!
To prevent damage to the water
pump, do not leave the control switch on SERVICE
for extended periods when water tank is empty.
Cleaning Rinse:
After
2 minutes
, remove the
Front Panel
, move the
control switch
to
ICE
. Replace the
Front Panel
.
After
3 minutes
, move the
service switch
to
WASH
, and
the
control switch
to
SERVICE
. Replace the
Front Panel
.
After
5 minutes
, remove the
Front Panel
, move the
service switch
to
DRAIN
. Replace the
Front Panel
After
2 minutes
, remove the
Front Panel
, move the
control
switch
to
OFF
.
Repeat 3x
(Steps
༗
thru
༚
Ϳ
to rinse thoroughly.
Continue to
Sanitation – Step
༜
on front
...
භ
Scoop
භ
Water Filters
භ
Exterior
භ
Bin Door/Top Kit
භ
Icemaker/Bin
භ
Water Supply Inlet
භ
Condenser
භ
Water Hoses
Dish soap, rinse well
Check psi, change if req’d
Dish soap & damp cloth
Warm water & clean cloth
Follow these instructions
Clean inlet screen
Inspect. Clean with brush
Inspect. Replace if req’d
භ
භ
භ
Tech Support: 1.800.233.1940
#51008 | 9.15.2016
!
sanitizing continued…
RINSE 1:
(Steps 20-22)
x
Move
control switch
to ICE,
replace front panel
x
After 3 minutes, remove the
front panel
x
Move
service switch
to WASH
and
control switch
to SERVICE,
replace the front panel
x
After 5 minutes, remove the
front panel
x
Move
service switch
to DRAIN,
replace the front panel
x
After 2 minutes, remove
the front panel
x
Move
control switch
to OFF,
replace the front panel
RINSE 2:
x
Repeat RINSE 1 (Steps 20–22)
for complete ice/food safety
x
Clean the dispenser unit /
ice storage bin liner with a
neutral cleaner (dish soap)
x
Rinse thoroughly
x
Move
control switch
to ICE,
replace front panel
DOWNLOAD COMPLETE
INSTRUCTION MANUAL:
hoshizakiamerica.com/manuals
Type in the model number of your
icemaker (including dashes) to
download manuals
ATTENTION!
DO NOT
use
ammonia type
cleaners. Can cause
damage to icemaker
WEAR
liquid-proof
gloves and goggles to
protect skin & eyes
from cleaning &
sanitizing chemicals
R
M
ϴ
A
ϵ
A
ϭϬ
A
ϭϭ
A
ϭϮ
AMMONIA
Cleaners
ϮϬ
e
Ϯϭ
ϮϮ
Ϯϯ
,
Ϯϱ
Ϯϰ
Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep
In
b
ϳ
After
30 min.
A
ϭϯ
R
ϭϰ
After
2 min.
After 3 min.
After 5 min.
After 2 min.
Repeat 3
x
ATTENTION!
IF ICEMAKER IS ON DISPENSER,
remember to turn on the dispenser
after cleaning
Page 21