24
Subject of Control
Description
Model
Purpose
Frame Heater
()
Remains OFF for max 15 min after
defrost cycle starts (until Interior Fan
Motor delay ends at longest)
HRE
Save energy
(2)
Remains OFF for 20 sec after
Compressor starts following drain cycle
HFE
Improve Compressor
startability
(3) Duty ratio is not updated and maintains
previous ratio after defrost cycle starts
and until Interior Fan Motor delay ends
HFE
Prevent
condensation
Interior Fan
Motor
(4) Remains ON for 5 sec after
Compressor starts following drain cycle
HRE-F
(Heater
defrost)
Improve Compressor
startability
HRE-F series (Heater defrost)
(2)
20 sec OFF
(3)
Update
(1)
duty ratio
Max 15 min OFF
duty ratio
Update duty ratio
Frame Heater
Compressor
Condenser
Fan Motor
(4)
5 sec ON
Interior
Fan Motor
Defrost Heater
Detects end of cycle (30°C)
Defrost (Interior)
Thermistor Temp
Defrost
Drain
Interior Display
(until Thermisto
5.5 min
FM delay
delay
detects)
5 min 3 min
Temp Display
Temp
"dF"
Temp
Maintain
Summary of Contents for HFE-140B Series
Page 6: ... 2 DIMENSIONS SPECIFICATIONS a HRE 70B ...
Page 7: ... b HRE 140B ...
Page 8: ... c HFE 70B ...
Page 9: ... d HFE 140B ...
Page 10: ... e HRE 70B F ...
Page 11: ... f HRE 140B F ...
Page 12: ... II TECHNICAL INFORMATION 1 WIRING DIAGRAM a HRE 70B ...
Page 13: ...10 b HRE 140B ...
Page 14: ...11 c HFE 70B ...
Page 15: ...12 d HFE 140B ...
Page 16: ...13 e HRE 70B F ...
Page 17: ...14 f HRE 140B F ...
Page 18: ...15 2 REFRIGERATION CIRCUIT Refrigerant HFC 134a HRE series HFC 404A HFE series ...