background image

Thermo Scientific

General Purpose, Flammable 

Storage, and Explosion Proof 

Laboratory Refrigerators and 

Freezers

Installation and Operation Manual

057-196-00 Rev. 

E

June 

2016

Visit us online to register your warranty
www.thermoscientific.com/labwarranty

Summary of Contents for 02LFEETSA

Page 1: ...l Purpose Flammable Storage and Explosion Proof Laboratory Refrigerators and Freezers Installation and Operation Manual 057 196 00 Rev E June 2016 Visit us online to register your warranty www thermoscientific com labwarranty ...

Page 2: ...rmed by qualified service personnel Material in this manual is for informational purposes only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific makes no representations or warranties with respect to this manual In no event shall Thermo be held liable for any damages direct or incidental arising from or related to the use of this manual 2016 Th...

Page 3: ...reezers and Freezers Explosion Proof Flammable Material Storage General Purpose 10ECEETSA 10FCEETSA 05LCEETSA 10ECEETSV 10FCEETSV 05LCEETSV 05EREETSA 05FREETSA 05LREETSA 05LREETSV 04LFEETSA 02LFEETSA 10LCEETSV 10LCEETSA 12LCEETSA ...

Page 4: ...nce 15 Electrical 16 Electrical Schematic 16 Be Advised 16 Operation 20 Environmental Operating Conditions 20 Start Up Procedure 20 Restart Procedure 20 Control Panel Lights 21 How to Save Energy 23 Safety Tips 24 Troubleshooting 25 Maintenance 26 Cleaning of Units 26 Interior Exterior and Door Gaskets 26 Condenser 26 Manual Defrost Procedure 26 Reversing the Front Door Model 10ECEETSA 28 Reversin...

Page 5: ...n addition this apparatus is not designed for use in Class I II or III locations as defined by the US National Electrical Code unless otherwise noted 1 1 Alert Signals ON OFF Safety Alert Important operating instructions To reduce the risk of injury or poor performance of the unit Read the user manual before putting the equipment into operation WARNING Indicates an immediately hazardous situation ...

Page 6: ...ed for use in research for the storage of samples or inventory in the following temperature ranges General Purpose Freezers 12 C to 25 C General Purpose Refrigerators 1 C to 12 C Explosion proof FMS Freezers 12 C to 20 C These are not considered medical devices and have therefore not been registered with a medical device regulatory body e g FDA that is it has not been evaluated for the storage of ...

Page 7: ...for extended periods of time The construction of our explosion proof units has been evaluated by Underwriters Laboratories UL and are suitable for use in classified areas requiring Class I Groups C and D protected equipment The electrical components such as thermostats wiring splices relays and compressor motors on explosion proof units are safely housed within explosion proof enclosures and condu...

Page 8: ... H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 10ECEETSA 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 28 6 151 77 x 60 x 72 64 cm 10ECEETSV 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 28 6 151 77 x 60...

Page 9: ...E INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED IT IS SUGGESTED THE UNIT BE RECESSED ONLY 21 TO PERMIT EASY ACCESS TO THE LOCK Note Amps listed are at normal run mode starting amps may be higher Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05EREETSA 27 7...

Page 10: ...the environment external to the unit Commonly known as Ordinary Locations FMS units are NOT designed for use in Class I Groups C and D environments which require an Explosion Proof Refrigerator Freezer FMS units are designed and evaluated by Underwriters Laboratories UL to meet the requirements of the National Fire Protection Association Standards Nos 45 70 and 99 These units have no internal elec...

Page 11: ...mber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm TotalVol Cu Ft Exterior Dimensions H x W x D inches cm 10FCEETSA 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 28 6 151 77 x 60 x 72 64 cm 10FCEETSV 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 28...

Page 12: ...OR FREE STANDING INSTALLATION ONLY THEY MAY BE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIRFLOW IS PROVIDED 1 ON THE SIDES TOP AND REAR ARE RECOMMENDED Note Amps listed are at normal run mode starting amps may be higher Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05FRE...

Page 13: ...ALLATION ONLY IT MAY BE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIRFLOW IS PROVIDED Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05LCEETSA 19 5 x 20 5 x 17 49 5 x 52 1 x 43 2 cm 5 x 19 x 11 5 12 7 x 48 3 x 29 2 cm 5 6 33 5 x 23 63 x 23 5 85 1 x 60 02 x 59 69 cm 05LCEET...

Page 14: ...Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05LREETSA 27 75 x 20 x 17 5 70 5 x 50 8 x 44 5 cm N A 5 5 33 5 x 23 63 x 23 5 85 1 x 60 02 x 59 69 cm 05LREETSV 27 75 x 20 x 17 5 70 5 x 50 8 x 44 5 cm N A 5 5 33 5 x 23 63 x 23 5 85 1 x 60 02 x 59 69 cm Model ElectricalCharacteristics Vol...

Page 15: ...ps listed are at normal run mode starting amps may be higher Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 04LFEETSA N A 24 25 x 17 75 x 16 5 61 6 X 45 09X 41 9 cm 3 5 33 5 x 23 63 x 23 5 85 1 x 60 02 x 59 69 cm Model Electrical Characteristics Volts Hz Amps Refrig Temp Range C F Free...

Page 16: ...ted are at normal run mode starting amps may be higher Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 02LFEETSA N A 18 63 x 13 38 x 13 47 32 x 33 9 x 39 02 cm 1 8 24 5 x 18 5 x 17 75 62 23 x 46 99 x 45 08 cm Model Electrical Characteristics Volts Hz Amps Refrig Temp Range C F Freezer T...

Page 17: ... D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 10LCEETSA 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 24 151 77 x 60 02 x 60 96 cm 10LCEETSV 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm 11 25 x 18 x 18 25 28 6 x 45 7 x 46 4 cm 10 1 59 75 x 23 63 x 24 151 77 x 60 02 x 60 96 cm Model Electrical Characteristics Volts Hz...

Page 18: ...compressors White color Note Amps listed are at normal run mode starting amps may be higher Model Refrigerator Chamber Dimensions H x W x D inches cm Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 12LCEETSA 35 25 x 19 75 x 18 5 89 5 x 50 2 x 46 99 cm 25 38 x 17 13 x 15 5 64 5 x 43 5 x 39 4 cm 11 8 79 x 23 63 x 23 75 200 7 x 60 02 x 63 5 cm Mo...

Page 19: ...cking Use the list below when unpacking to verify that the complete unit has been received Do not discard packing materials until all is accounted for The following items are included in the shipment 5 3 Location Locate your unit in the most convenient place and near a grounded electric outlet If units are placed on a counter top the front should be 3 or more back from the edge to avoid accidental...

Page 20: ...nding prongs from the 3 prong power cord supplied with all units CAUTION DO NOT USE electrical extension cords that may result in voltage loss and possible hazardous operation 5 6 Electrical Schematic Figure 1 Electrical Schematic of the 02LFEETSA Freezer 5 7 Be Advised WARNING Explosion proof units do not come with line cords They require rigid conduit to be run directly in order to seal off the ...

Page 21: ...UCT SHALL BE DEEMED TO CONSTITUTE ABNORMAL AND IMPROPER USAGE OF THE PRODUCT FOR PURPOSES OF THIS WARRANTY WARNING RISK OF CHILD ENTRAPMENT Before you discard your old refrigerator or freezer Remove door s Leave the shelves in place so that children may not easily climb inside How to Seal Killark Box Conduit with Fiber and Sealing Compound to Help Protect Against Explosions Explosion Proof Units O...

Page 22: ... of water while stirring until a thick paste is formed then carefully continue adding smaller amounts of water until a thick gravy consistency is achieved NOT WATERY Discard any material that becomes too stiff to use Never attempt to restore workability by stirring in more water Locate silver Killark box back top center of unit Unscrew conduit domed cover Figure 2 Sealing the Killark Box Figure 3 ...

Page 23: ...g Pressing down firmly work the material into the right hub and most importantly being sure the material COMPLETELY SURROUNDS THE WIRING from the top to the bottom completely blocking this end of the horizontal conduit Pour sealing compound down in between the two fiber rope dams filling the remaining space Pour slowly being careful not to trap air bubbles Immediately wipe off any spilled sealing ...

Page 24: ...r the chamber temperature to stabilize after subsequent temperature adjustments Because the markings on the dial do not indicate specific temperatures use them AS REFERENCE POINTS ONLY for any future setting of the temperature If the room thermostat is turned below 60ºF at night consider setting the temperature control one step colder It should be left at this setting for the night time period ret...

Page 25: ... light is off The interior temperature is controlled by the thermostat which turns the cooling system on and off The frequency of switching the cooling system on and off depends on The thermostat knob position thermostat setting How often you open the door and Ambient temperature Temperature Selection When the freezer operates automatically the interior temperature is controlled by the thermostat ...

Page 26: ...towards min help you save energy provided that the freezer is loaded with smaller amount Change of the ambient temperature affects temperature in the interior of the appliance Choose correct setting of the thermostat knob Red Control Light The red light is on when there is something wrong with the temperature in the freezer ...

Page 27: ... other materials before placing them in a unit Don t overcrowd the unit Too many items can increase electrical energy demand in order to keep everything cool Close the door as soon as possible in hot humid weather Make certain that the door is closed tightly As soon as frost has accumulated to 1 4 defrost Keep containers covered when possible to reduce moisture buildup Set operating temperature no...

Page 28: ... touch the cold surfaces particularly when hands are damp Skin may adhere to the extremely cold surfaces Never disconnect your unit by pulling on the power cord Always grip the plug securely and pull straight out from the outlet Do not use a power cord that shows cracks or abrasions Have a qualified electrician repair or replace damaged cords immediately ...

Page 29: ...d with a dry brush or vacuum A leak around the door gasket will allow cold air to escape This causes unit to work harder than necessary to maintain cold temperatures Re seat or replace the gasket if worn If you have temperature set too cold this may cause unit to run continuously Check optimum running temperature Is the ambient air over 43ºC 109ºF or the units located close to heat sources If poss...

Page 30: ...ded beyond what the distributor can provide please call Customer Service at 800 438 4851 No merchandise should be returned directly to the factory without obtaining a Return Materials Authorization RMA number from Customer Service 10 2 Interior Exterior and Door Gaskets A solution of mild soap and water can be used for cleaning the interior exterior and door gaskets with a soft clean cloth Rinse w...

Page 31: ...f warm water inside the chamber Wipe out the interior Replace contents Reconnect power cord to outlet and set temperature control to desired operating temperature CAUTION Do not use any sharp instrument blade or scraper to remove ice and frost on refrigerator surfaces because of the very real danger of puncturing the cooling coil CAUTION Do not use any electrical device to defrost the unit When fr...

Page 32: ...e on the opposite side and fit the hinge washer 11 Refit the door 12 Locate the top hinge in the door and loosely attach to the cabinet 13 Align the door and then tighten screws firmly on the top hinge Check that the door open and closes easily Make sure there are no gaps that would allow air into the cabinet adjust the top hinge if necessary 10 6 Reversing the Front Door Model 05FREETSA 05EREETSA...

Page 33: ...ion of the door by eyesight then tighten the bolts of the upper hinges 13 Fit the upper platform into its place 14 Fit the bolts connecting the upper hinges and the upper platform but do not tighten them 15 Adjust the upper platform until it is level then tighten the bolts in operations 16 Fit the plugs of the upper platform 10 7 Reversing the Front Door Model 12LCEETSA 1 Turn thermostats to 0 and...

Page 34: ... plastic caps on the new middle hinge side Remove screw and mount lower door and fasten middle hinge 9 Remove the door handle by removing mounting screws and remount on opposite side 10 Mount the upper door on pivot and fasten the upper hinge on opposite side then tighten screws 11 For adjustment of doors loosen screws and reposition door into place and tighten screws 12 Move handle to opposite si...

Page 35: ...al 31 10 8 Reversing the Front Door Model 02LFEETSA This appliance has the capability of the door opening from either the left or the right side The unit is delivered to you with the door opening from the left side Should you desire to reverse the opening direction you can refer to the diagram below ...

Page 36: ...rigerators and Freezers 11 Replacement Parts To obtain replacement parts information and pricing please call the Customer Service Department at 1 800 438 4851 and have the unit s model serial and code numbers available This information is located on data plates on the left side of the unit ...

Page 37: ...All parts listed herein may be ordered from the Thermo Scientific dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your request then contact our Customer Service Department at 800 438 4851 Prior to returning any materials please contact our Cust...

Page 38: ...her force or effect if there is any i repair made to the product by a party other than the manufacturer or its duly authorized service representative ii misuse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or third party or iii use of replacement parts that are obtained ...

Page 39: ...inden Sie unter www thermo com Conformità WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2012 19 EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE È marcato col seguente simbolo Thermo Fischer Scientific ha stipulato contratti con una o diverse società di riciclaggio smaltimento in ognuno degli Stati Membri Europei Questo prodotto verrà smaltito o rici...

Page 40: ...tion and purchase order number IF YOU NEED ASSISTANCE Thermo Scientific products are backed by a global technical support team ready to support your applications We also offer cold storage accessories including remote alarms temperature recorders and validation services Visit www thermoscientific com or call Model Number Serial Number Date Purchased SALES DIVISION Phone 828 658 2711 800 252 7100 F...

Page 41: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 057 196 00 Rev E ...

Reviews: