Power Supply Board
Screw M4 x 8
Top View of Relay Box
Board Support
2. RELAY BOX
[a] POWER SUPPLY BOARD
1) Unplug the unit.
2) Disconnect the connectors.
3) Loosen and remove the two Board Supports at the back.
4) Loosen the three screws from outside the Relay Box,
and remove the Power Supply Board. Do not remove
the screws from inside the Relay Box, or the parts may
fall off the Power Supply Board.
5) To replace the removed parts, reverse the above
procedure.
Note: 1. The Power Supply Board is connected to a commercial power supply. Be sure
to disconnect the power supply before servicing.
2. Some parts may have become hot just after operation. Handle with care.
3. REFRIGERATION CIRCUIT
[a] COMPRESSOR
1) Unplug the unit.
2) Remove the Front Panel.
3) Remove the Top Panel.
4) Remove the Protector Cover enclosing the electrical parts. Remove the Overload
Relay, Starting Relay, and other parts.
5) Recover the refrigerant from the low side Access Valve.
6) Disconnect the discharge and suction pipes by using brazing equipment.
7) Remove the hexagon bolts securing the Compressor.
8) To replace the removed parts, reverse the above procedure.
Summary of Contents for HFE-140B Series
Page 6: ... 2 DIMENSIONS SPECIFICATIONS a HRE 70B ...
Page 7: ... b HRE 140B ...
Page 8: ... c HFE 70B ...
Page 9: ... d HFE 140B ...
Page 10: ... e HRE 70B F ...
Page 11: ... f HRE 140B F ...
Page 12: ... II TECHNICAL INFORMATION 1 WIRING DIAGRAM a HRE 70B ...
Page 13: ...10 b HRE 140B ...
Page 14: ...11 c HFE 70B ...
Page 15: ...12 d HFE 140B ...
Page 16: ...13 e HRE 70B F ...
Page 17: ...14 f HRE 140B F ...
Page 18: ...15 2 REFRIGERATION CIRCUIT Refrigerant HFC 134a HRE series HFC 404A HFE series ...