40
Defrost Thermistor
Fan Motor Side
Bottom
Defrost Thermistor
Fan Motor Side
Bottom
not to press hard on the bulbs and leads.
5) Remove the Clog Thermistor Bulb by removing the Thermistor Holder located at the
center or outlet of the Condenser.
6) Remove the Control Box, and disconnect the Thermistor connectors.
Note: 1. To replace the removed parts, reverse the above procedure.
2. To prevent the Evaporator from freezing, use the Bush - Thermistor to securely
plug the wiring hole in the Refrigeration Unit Base.
Interior Thermistor Bulb Location
Defrost Thermistor Bulb Location
HRE (Off-cycle defrost)
HFE