8
F-800MWH-C
AC SUPPLY VOLTAGE
115-120/60/1
COMPRESSOR
120 V
9.2 RLA
60 LRA
GEAR MOTOR
120 V
1.6 FLA
1/6 HP
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
W ATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*670 (304)
650 (295)
640 (290)
Reference without *marks
80
625 (284)
615 (279)
605 (274)
90
590 (268)
*590 (268)
570 (258)
100
560 (253)
550 (249)
*505 (229)
SHAPE OF ICE
Cubelet
ICE QUALITY
Approx. 80% , Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & W ATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kW H/100 lbs.)
1155 (4.7)
1140 (4.1)
POTABLE W ATER
71 (12)
81 (12)
W ATER-COOLED CONDENSER
553 (94)
318 (47)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (W xDxH)
22" x 27-3/8" x 25-1/4" (560 x 695 x 642mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
W EIGHT
Net 172 lbs. ( 78 kg ), Shipping 198 lbs. ( 90 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- W ATER SUPPLY
Inlet 1/2" FPT
Cond. Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
Cond. Outlet 3/8"-18 NPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING W ATER CONTROL
Float Switch
COOLING W ATER CONTROL
Automatic W ater Regulator
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model RS55-C1E-PAA
CONDENSER
W ater-cooled, Tube in tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
13oz.
(365g)
DESIGN PRESSURE
High 427 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Manual reset Circuit Breaker or Fuse
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW W ATER PROTECTION
Float Switch and Timer
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 - 100° F
W ATER SUPPLY TEMP.
45 - 90° F
W ATER SUPPLY PRESSURE
10 - 113 PSIG
* W e reserve the right to make changes in specifications and design without prior notice.
Summary of Contents for F-800MAH
Page 13: ...13 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAH C...
Page 14: ...14 F 800MWH C...
Page 15: ...15 2 WIRING DIAGRAM F 800MAH C F 800MWH C...
Page 17: ...17 b When Reservoir has been filled Gear Motor starts immediately...
Page 18: ...18 c Compressor starts about 60 sec after Gear Motor starts...
Page 19: ...19 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously...
Page 20: ...20 e Low Water Except Water cooled Model...
Page 23: ...23 h When Flush Timer operates for 15 min every 12 hours...
Page 26: ...26 4 TIMING CHART...
Page 27: ...27...
Page 28: ...28...