54
2. CLEANING INSTRUCTIONS
WARNING
1. HOSHIZAKI recommends cleaning this unit at least once a year. More
frequent cleaning, however, may be required in some existing water
conditions.
2. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
3. Always wear liquid-proof gloves for safe handling of the cleaning and
sanitizing solution. This will prevent irritation in case the solution contacts
with skin.
<STEP 1>
Dilute the solutions with water as follows.
Cleaning solution: 4.8 fl. oz. of recommended cleaner Hoshizaki “Scale Away” or
“LIME-A-WAY” (Economics Laboratory, Inc.) with 0.8 gal. of water.
This is a minimum amount. Make more solution, if necessary.
Sanitizing solution:
2.5 fl. oz. of IMS-II Sanitizer or a 5.25 % sodium hypochlorite
solution with 5 gal. of water.
Note: IMS-II Sanitizer, Part #SA0004, is available through your Hoshizaki Dealer.
Dilute the solutions with water as follows.
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after
dilution.
<STEP 2>
Use the cleaning solution to remove lime deposits in the water system.
1) Turn off the power supply.
2) Close the Water Supply Line Shut-off Valve.
3) Remove all ice from the Storage Bin.
4) Remove the Front Panel and the Top Panel.
5) Move the Flush Switch to the “FLUSH” position.
Summary of Contents for F-800MAH
Page 13: ...13 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAH C...
Page 14: ...14 F 800MWH C...
Page 15: ...15 2 WIRING DIAGRAM F 800MAH C F 800MWH C...
Page 17: ...17 b When Reservoir has been filled Gear Motor starts immediately...
Page 18: ...18 c Compressor starts about 60 sec after Gear Motor starts...
Page 19: ...19 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously...
Page 20: ...20 e Low Water Except Water cooled Model...
Page 23: ...23 h When Flush Timer operates for 15 min every 12 hours...
Page 26: ...26 4 TIMING CHART...
Page 27: ...27...
Page 28: ...28...