5) Replace the Cover of the Reservoir and the Control Water Valve in their correct position.
6) Move the Flush Switch to the “ICE” position.
7) Replace the Top Panel and the Front Panel in their correct position.
8) Allow the icemaker to set for about 10 minutes before the operation. Then, turn on the
power supply, and make ice using the solution until the icemaker stops icemaking.
9) Remove the Front Panel.
10) Move the Flush Switch to the “FLUSH” position to drain the sanitizing solution.
11) Move the Flush Switch to the “ICE” position.
12) Replace the Front Panel in its correct position.
13) Open the Water Supply Line Shut-off Valve, and supply water to the Reservoir.
14) Turn off the power supply when the Gear Motor starts.
15) Drain out all water from the water line. See 4) through 7) in STEP 2.
16) Move the Flush Switch to the “ICE” position.
<STEP 4>
Use the sanitizing solution to sanitize removed parts.
1) Remove the Thumbscrew securing the Bin Control Switch on the Chute Assembly.
2) Remove the Band connecting the Spout with the Chute Assembly, and take out the
Chute Assembly from the icemaker.
3) Remove the Gasket at the bottom of the Ice Chute and another at the Spout.
4) Remove the three Ties and the Insulation of the Chute.
5) Remove the six Wing Nuts and two Baffles.
IMPORTANT
When installing the Baffles, make sure that the bent surface (the one without
the studs) faces the Activator so that the bent surface can guide the ice to the
center of the Activator.
Summary of Contents for F-800MAH
Page 13: ...13 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAH C...
Page 14: ...14 F 800MWH C...
Page 15: ...15 2 WIRING DIAGRAM F 800MAH C F 800MWH C...
Page 17: ...17 b When Reservoir has been filled Gear Motor starts immediately...
Page 18: ...18 c Compressor starts about 60 sec after Gear Motor starts...
Page 19: ...19 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously...
Page 20: ...20 e Low Water Except Water cooled Model...
Page 23: ...23 h When Flush Timer operates for 15 min every 12 hours...
Page 26: ...26 4 TIMING CHART...
Page 27: ...27...
Page 28: ...28...