58
3. MAINTENANCE
IMPORTANT
1. This icemaker must be maintained individually, referring to the instruction
manual and labels provided with the icemaker.
2. To have the optimum performance of this icemaker, the following consumable
parts need periodical inspection, maintenance and replacement:
Extruding Head
Housing
Gear Motor
Auger
Mechanical Seal
These parts should be inspected at least once a year or every 10,000 hours
of operation. Their service life, however, depends on water quality and
environment. More frequent inspection and maintenance are recommended.
Consult with your local distributor about inspection and maintenance
service. To obtain the name and phone number of your local distributor, call
Hoshizaki Technical Support at 1-800-233-1940.
1) Stainless Steel Exterior
To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use
a damp cloth containing a neutral cleaner to wipe off oil or dirt build up.
2) Storage Bin and Scoop
* Wash your hands before removing ice. Use the plastic scoop provided (Bin
accessory).
* The Storage Bin is for ice use only. Do not store anything else in the bin.
* Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly.
* Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
Summary of Contents for F-800MAH
Page 13: ...13 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAH C...
Page 14: ...14 F 800MWH C...
Page 15: ...15 2 WIRING DIAGRAM F 800MAH C F 800MWH C...
Page 17: ...17 b When Reservoir has been filled Gear Motor starts immediately...
Page 18: ...18 c Compressor starts about 60 sec after Gear Motor starts...
Page 19: ...19 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously...
Page 20: ...20 e Low Water Except Water cooled Model...
Page 23: ...23 h When Flush Timer operates for 15 min every 12 hours...
Page 26: ...26 4 TIMING CHART...
Page 27: ...27...
Page 28: ...28...