39
F-1500MWH
APPROXIMATE
Ambient
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
1435
652
1390
632
1360
618
80
1335
607
1310
595
1285
584
90
1260
573
1245
566
1210
550
lbs./DAY kg/day
100
1185
539
1160
527
1075
489
APPROXIMATE ELECTRIC
70
1792
--
1780
--
1780
--
CONSUMPTION
80
1792
--
1780
--
1780
--
90
1792
--
1780
--
1780
--
watts
100
1792
--
1780
--
1780
--
APPROXIMATE WATER
70
606
2294
760
2877
1172
4437
CONSUMPTION PER 24 HR.
80
632
2393
793
3002
1232
4664
TOTAL
90
656
2484
823
3116
1298
4914
gal. / day kg/day
100
683
2586
857
3245
1432
5421
EVAPORATOR OUTLET TEMP
70
25
-4
25
-4
25
-4
F C
80
25
-4
25
-4
25
-4
90
25
-4
25
-4
25
-4
100
25
-4
25
-4
25
-4
HEAD PRESSURE
70
262
18.4
263
18.5
265
18.6
80
262
18.4
263
18.5
265
18.6
90
262
18.4
263
18.5
265
18.6
PSIG kg/sq.cmG
100
262
18.4
263
18.5
265
18.6
SUCTION PRESSURE
70
40
2.8
40
2.8
41
2.9
PSIG kg/sq.cmG
90
40
2.8
40
2.8
41
2.9
80
40
2.8
40
2.8
41
2.9
100
40
2.8
40
2.8
41
2.9
TOTAL HEAT OF REJECTION FROM CONDENSER 13,874 BTU/h (AT 90 F /WT 70 F)
TOTAL HEAT OF REJECTION FROM UNIT
2,109 BTU/h (AT 90 F /WT 70 F)
* We reserve the right to make changes to specifications and design without prior notice.
Water Temp. (F)
50
70
90
Summary of Contents for F-1500MA-C
Page 11: ...11 2 Condenser Unit URC 12F...
Page 18: ...18 III Technical Information 1 Water Circuit and Refrigeration Circuit F 1500MAH C...
Page 19: ...19 F 1500MWH C...
Page 20: ...20 F 1500MRH C...
Page 21: ...21 2 Wiring Diagrams F 1500MAH C...
Page 22: ...22 F 1500MWH C...
Page 23: ...23 F 1500MRH C...
Page 25: ...25 b When reservoir has been filled gear motor starts immediately...
Page 26: ...26 c Compressor starts about 60 sec after gear motor starts...
Page 27: ...27 d Bin control operates and about 6 sec later compressor and gear motor stop simultaneously...
Page 28: ...28 e Low water except water cooled model...
Page 32: ...32 4 Timing Chart...
Page 33: ...33...
Page 34: ...34...
Page 35: ...35...
Page 36: ...36...