61
9. Removal and Replacement of Fan Motor
1) Turn off the power supply and remove the panels.
2) Remove the wire connectors from the fan motor leads.
3) Remove the fan motor bracket and fan motor.
4) Install the new fan motor.
5) Replace the panels in their correct position, and turn on the power supply.
10. Removal and Replacement of Control Water Valve
1) Turn off the power supply, remove the panels and close the water supply line shut-off
valve.
2) Disconnect the terminals from the control water valve.
3) Loosen the fitting nut on the control water valve inlets, and remove the control water
valve.
4) Remove the water supply hose from the control water valve.
5) Install the new control water valve.
6) Assemble the removed parts in the reverse order of the above procedure.
7) Open the water supply line shut-off valve.
8) Check for water leaks.
9) Replace the panels in their correct position, and turn on the power supply.
Summary of Contents for F-1500MA-C
Page 11: ...11 2 Condenser Unit URC 12F...
Page 18: ...18 III Technical Information 1 Water Circuit and Refrigeration Circuit F 1500MAH C...
Page 19: ...19 F 1500MWH C...
Page 20: ...20 F 1500MRH C...
Page 21: ...21 2 Wiring Diagrams F 1500MAH C...
Page 22: ...22 F 1500MWH C...
Page 23: ...23 F 1500MRH C...
Page 25: ...25 b When reservoir has been filled gear motor starts immediately...
Page 26: ...26 c Compressor starts about 60 sec after gear motor starts...
Page 27: ...27 d Bin control operates and about 6 sec later compressor and gear motor stop simultaneously...
Page 28: ...28 e Low water except water cooled model...
Page 32: ...32 4 Timing Chart...
Page 33: ...33...
Page 34: ...34...
Page 35: ...35...
Page 36: ...36...