38
F-1500MAH-C
APPROXIMATE
Ambient
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
1300
590
1245
565
1194
542
80
1145
520
1099
498
1054
478
90
1011
458
990
449
930
422
lbs./DAY kg/day
100
892
404
855
388
800
363
APPROXIMATE ELECTRIC
70
1820
--
1826
--
1832
--
CONSUMPTION
80
1838
--
1845
--
1851
--
90
1857
--
1863
--
1867
--
watts
100
1872
--
1876
--
1880
--
APPROXIMATE WATER
70
156
590
149
565
143
542
CONSUMPTION PER 24 HR.
80
138
520
132
498
127
478
90
121
458
119
449
112
422
gal. / day l/day
100
107
404
103
388
96
363
EVAPORATOR OUTLET TEMP
70
16
-9
16
-9
16
-9
F C
80
16
-9
18
-8
18
-8
90
18
-8
18
-8
19
-7
100
19
-7
19
-7
19
-7
HEAD PRESSURE
70
210
14.8
210
14.8
210
14.8
80
240
16.9
240
16.9
240
16.9
90
270
19.0
270
19.0
270
19.0
PSIG kg/sq.cmG
100
310
21.8
310
21.8
310
21.8
SUCTION PRESSURE
70
35
2.5
35
2.5
35
2.5
PSIG kg/sq.cmG
90
38
2.6
38
2.6
38
2.6
80
40
2.8
40
2.8
40
2.8
100
42
3.0
42
3.0
42
3.0
TOTAL HEAT OF REJECTION 15,323 BTU/h (AT 90 F /WT 70 F)
* We reserve the right to make changes to specifications and design without prior notice.
Water Temp. (F)
50
70
90
Summary of Contents for F-1500MA-C
Page 11: ...11 2 Condenser Unit URC 12F...
Page 18: ...18 III Technical Information 1 Water Circuit and Refrigeration Circuit F 1500MAH C...
Page 19: ...19 F 1500MWH C...
Page 20: ...20 F 1500MRH C...
Page 21: ...21 2 Wiring Diagrams F 1500MAH C...
Page 22: ...22 F 1500MWH C...
Page 23: ...23 F 1500MRH C...
Page 25: ...25 b When reservoir has been filled gear motor starts immediately...
Page 26: ...26 c Compressor starts about 60 sec after gear motor starts...
Page 27: ...27 d Bin control operates and about 6 sec later compressor and gear motor stop simultaneously...
Page 28: ...28 e Low water except water cooled model...
Page 32: ...32 4 Timing Chart...
Page 33: ...33...
Page 34: ...34...
Page 35: ...35...
Page 36: ...36...