HOSHIZAKI EUROPE B.V.
Cabinets on feet require an even, durable floor. Cabinets on feet are levelled by turning
the internal part of the feet (see figure):
Cabinets on castors require a level, even and durable floor to provide a stable foundation. Aftercorrectly
positioning the device, the two brakes on the front castors must be applied (see figure)
Devices on castors must not be placed on a platform.
The cabinets are equipped with a chamber for re-evaporation of the condensation water on top of the
cabinets. This equipment is intended for the amount of condensation water that accumulates on average
with a maximum of 72 door openings per day according to EN16825.
The actual amount of condensation water may vary depending on usage and ambient conditions. If the
number of door openings per day exceeds 72, or the condensation water pan overflows due to other usage
factors, the user must use the product strictly under the specified conditions to prevent overflow.
If the amount of condensation increases despite not changing the usage or the ambient conditions, the device
may have a defective door seal or a door that does not close properly.
8
Condensation water re-evaporation
Devices on castors
Devices on feet