HOSHIZAKI EUROPE B.V.
Depending on the temperature and air humidity at the installation site as well as the selected set point
setting, the water in the ambient air can condense on the surface of a refrigerating unit due to its design.
If several cooling or refrigeration units are set up side by side, this condensation effect becomes stronger,
and a lower air quantity can circulate between the devices. As a result, a minimum distance of
30 to 50 mm
must be kept between the devices depending on the temperature and air humidity.
These gaps must not be sealed either at the top or bottom, but can be covered by a stainless-steel panel
from the front for aesthetic purposes. The panel must be removable for cleaning within the gaps.
If it is not possible for air to circulate freely at the bottom, e.g. due to a base installation, then thegaps
cannot be sealed at the front.
5
Air circulation
30
– 50 mm depending
on the ambient
temperature and air
humidity.
Setting up several devices side by side