HOSHIZAKI EUROPE B.V.
Press the key
for approx. 2 seconds until
“rCH” appears, then press
until
“Pb2”
is
displayed. The evaporator temperature is displayed after pressing the key
. The display disappears
after briefly pressing
or
, or automatically after 60 seconds without touching any keys.
Press the key
for approx. 2 seconds until
“rCH” appears, then press
until
“Pb1”
is
displayed. The room temperature is displayed after pressing the key
. The display disappears after
briefly pressing
or
, or automatically after 60 seconds without touching any keys.
Press the key
for approx. 2 seconds until
“rCH” appears, then press
until
“CH”
is
displayed. The counter reading is displayed after pressing the key
. The display disappearsafter
briefly pressing
or
, or automatically after 60 seconds without touching any keys.
Press the key
for approx. 2 seconds until
“rCH” appears. If required, press
until
“rCH”
is displayed.
Briefly press the key
;
”0” is displayed. Within 15 seconds, press the key
or
to input the password
”149” for resetting the counter and briefly press
.
The indicator
” - -“ flashes on the display for 4 seconds. The counter has been reset.
The controller does not manage separate user parameters except for the temperature set point
“SP”. The alarm settings are configured in the configuration parameters; see below.
15
Setting the alarm limits
Deleting the compressor run time (operating time counter)
Compressor run time display (operating time counter)
Room sensor temperature display
Evaporator sensor temperature display
Summary of Contents for 877000901
Page 26: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 26 Dimensions...
Page 27: ...HOSHIZAKI EUROPE B V SUR 65EG SUF 65EG 27 Dimensions...
Page 28: ...HOSHIZAKI EUROPE B V 28 Wiring diagram...
Page 29: ...HOSHIZAKI EUROPE B V 29 Wiring diagram...
Page 31: ...HOSHIZAKI EUROPE B V 31 EU Declaration of Conformity SUR SUF EG...
Page 32: ...HOSHIZAKI EUROPE B V 32 UKCA Declaration of Conformity SUR SUF EG...