Troubleshooting
Malfunction
Possible cause
Remedy
The placing quantity is too low.
The sealing lip in the metering
unit is worn.
Replace the sealing lip.
The placing quantity is set too
low.
Check the adjustment on
the terminal and correct as
required.
The pressurized hopper of the
seed wagon is leaking.
Check the hopper for leak
tightness and replace the
seals if necessary.
The pneumatic system is
leaking.
Check the distributor and
all pneumatic hoses for
leak tightness. Replace the
respective components if
necessary.
Sporadic skipping of work
signal.
The control unit on the tractor
is set incorrectly.
Switch the control units on the
tractor to the correct position,
see
Field work
.
56