164
9.2.3 Setting Occupied Point
Occupied points can be set by two setting methods:
1) Setting from the coordinate data stored in the internal memory
2) Direct key input of coordinate data
Setting the occupied point from the internal coordinate data file.
Operation procedure
Operation
Display
① Press the F1 (0CC. PT
INPUT) key from the Layout
menu 1/2.
F1
②The point can be manually
entered or retrieved by F2
LIST. Press ENT key to
confirm.
ENT
③Press the F4 (YES) key to
get to the instrument height.
F4
④Enter INS.HT press ENT.
The display returns to layout
menu 1/2.
Enter
INS.HT
ENT
*1)Refer to Section 1.10 “How to Enter Alphanumeric characters”