![hopf 6842 GPS Technical Manual Download Page 63](http://html1.mh-extra.com/html/hopf/6842-gps/6842-gps_technical-manual_2161862063.webp)
COM0 / COM1 S
ERIAL
I
NTERFACES
6842 GPS Slim Line System - V09.01
63 / 98
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
5.3.7
hopf
Master/Slave-String
The
hopf
Master/Slave-String can be used to synchronise slave systems with the time data
of the master system up to an accuracy of ± 0.5msec. It differs from the
hopf
DCF77 slave
string in as much as the difference to the UTC time is included in the transmission.
The
hopf
Master/Slave-String transmits:
•
the full time information (hour, minute, second)
•
the date (day, month, year [2 digits])
•
the difference time local to UTC (hour, minute)
•
the day of the week
•
and status information (announcement of ST/WT change over, announcement of
a leap second and the status of reception of the Master/Slave-String source)
5.3.7.1 Specified Settings
Automatic:
no
Required:
The following settings are required for the synchronisation of the
hopf
_
slave-systems:
•
output every minute
•
output second forerun
•
ETX on the second change; selectable: data string at the
beginning or at the end of the 59. second.
•
local time
•
9600 baud, 8 bit, 1 stop bit, no parity
This setting guarantees the best control of the time basis in the
slave systems.
Blocked:
no