5 - 8
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
1234567890**ABCDEFGHIJ
<CR>
Insert symbology name
B3 Insert the name of the bar code’s symbology in the output message,
without moving the cursor. Only symbologies with a Honeywell ID are
included (see
on page A-1). Refer to the
Conversion Chart (Code Page 1252),
decimal, hex and character codes.
Insert bar code length
B4 Insert the bar code’s length in the output message, without moving the
cursor. The length is expressed as a numeric string and does not
include leading zeroes.
B3 and B4 Example: Insert the symbology name and length
Send the symbology name and length before the bar code data from
the bar code above. Break up these insertions with spaces. End with
a carriage return.
Command string:
B3F42001B4F42001F10D
B3 is the “Insert symbology name” command
F4 is the “Insert a character multiple times” command
20 is the hex value for a space
01 is the number of times the space character is sent
B4 is the “Insert bar code length” command
F4 is the “Insert a character multiple times” command
20 is the hex value for a space
01 is the number of times the space character is sent
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
Code128 20 1234567890ABCDEFGHIJ
<CR>
Summary of Contents for Vuquest 3310g
Page 1: ... Vuquest 3310g Area Imaging Scanner User s Guide ...
Page 8: ......
Page 17: ...ix Unicode Key Maps A 13 ...
Page 18: ...x ...
Page 24: ...1 6 ...
Page 80: ...3 30 ...
Page 88: ...4 8 ...
Page 108: ...5 20 ...
Page 196: ...8 20 ...
Page 200: ...9 4 ...
Page 206: ...10 6 ...
Page 246: ...11 40 ...
Page 256: ...13 4 ...
Page 272: ...A 14 ...
Page 275: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...