RESTART
RESTART
RESTART
RESTART
Restart
Restart
Restart
Restart
R/W
Allows a manual restart to be initiated. Several degrees of
restart are possible. They are 1: Run, 2: Restart resource, 3:
Restart with defaults and 4: Restart processor.
Run
Setting:
Run / Resource / Defaults / Processor
RS_STATE
RS_STATE
RS_STATE
RS_STATE
Resource State
Resource State
Resource State
Resource State
R
State of the function block application state machine.
Standby
Setting:
Uninitialized / Start_Restart / Initialization / Online Linking /
Online / Standby / Failure
SET_FSTATE
SET_FSTATE
SET_FSTATE
SET_FSTATE
Set Fault State
Set Fault State
Set Fault State
Set Fault State
R/W
Allows the fault state condition to be manually initiated by
selecting "Set".
Off
Setting:
Uninitialized / Off / Set
SHED_RCAS
SHED_RCAS
SHED_RCAS
SHED_RCAS
Shed Remote Out
Shed Remote Out
Shed Remote Out
Shed Remote Out
R/W
Time duration at which to give up on computer writes to
function block RCAS locations. Shed from RCAS shall never
happen when SHED_RCAS = 0.
640000
Setting:
0...4294967295 in [1/32 ms]
SHED_ROUT
SHED_ROUT
SHED_ROUT
SHED_ROUT
Shed Remote Out
Shed Remote Out
Shed Remote Out
Shed Remote Out
R/W
Time duration at which to give up on computer writes to
function block RCAS locations.
640000
Setting:
0...4294967295 in [1/32 ms]
TEST_RW
TEST_RW
TEST_RW
TEST_RW
Test Read Write
Test Read Write
Test Read Write
Test Read Write
R/W
Read/write test parameter - used only for conformance
testing.
Note: Subelements "Value 1..15" have no function!
-
UPDATE_EVT
UPDATE_EVT
UPDATE_EVT
UPDATE_EVT
Update Event
Update Event
Update Event
Update Event
Mix
This alert is generated by any change to the static data.
-
Unacknowledged
R/W
A discrete enumeration which is set to "Unacknowledged"
when an alarm occurs, and set to "Acknowledged" by a write
from a human interface device or other entity which can
acknowledge that the alarm/event has been noticed.
Uninitialized
Setting:
Uninitialized / Acknowledged / Unacknowledged
Update State
R
A discrete enumeration which gives an indication of whether
the alert has been reported.
Uninitialized
Setting:
Uninitialized / Reported / Not reported
Time Stamp
R
The time when evaluation of the block was started and a
change in alarm/event state was detected that is unreported.
The time stamp value will be maintained constant until alert
confirmation has been received - even if another change of
state occurs.
Uninitialized
Setting:
MM / DD / YY (Month / Day / Year)
HH:MM:SS (Hour:Minute:Second)
Static Revision
R
The static revision of the block whose static parameter was
changed and is being reported. It is possible for the present
value of static revision to be greater than this because static
can be changed at any time.
0
Setting:
0
…
65535
Parameter
Parameter
Parameter
Parameter
Subelement
Access
Description and settings
Initial Value
Summary of Contents for TWM 9000
Page 4: ...1 SAFETY INSTRUCTIONS 4 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...
Page 6: ...2 TECHNICAL DATA 6 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...
Page 60: ...4 OPERATION 60 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...
Page 61: ...OPERATION 4 61 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...
Page 62: ...4 OPERATION 62 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...
Page 63: ...OPERATION 4 63 TWM 9000 www honeywellprocess com 34 VF 25 37 iss 2 GLO Jan 18 US ...