Configuring via the Web Server
Configuring Other I/O & Groups Tab
The Groups tab enables you to:
•
Associate any of the panel’s eight output relays in one or more groups.
•
Configure the following for each group:
– Pulse Time
– Energized TZ (Time Zone)
– Interlock Disabled TZ (Time Zone)
– Latch
Steps
: Use the descriptions in the following table to configure each group:
Table 2-12: Configuration > Other I/O & Groups > Groups Tab Field Descriptions
Setting
Description
Name
Enter a unique name to identify the group.
Pulse Time
Specifies the duration for which the device will assume
abnormal status. For example, it specifies how long a horn will
blow or a door strike will remain released. Enter the desired
number of hours (1024 maximum), minutes (60 maximum), and
seconds (60 maximum). The sum of all three units comprises the
pulse time. Note that you can express seconds in tenths of a
second.
Energized TZ
Specifies the period during which the group of output relays are
automatically energized.
Interlock Disabled
TZ
Specifies the period during which the interlocks that control the
group’s outputs will be disabled.
Latch
Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock,
or manual pulse).
Summary of Contents for NetAXS
Page 8: ...viii www honeywell com ...
Page 18: ...1 10 www honeywell com Connecting to the Web Server Reading the Select Panel ...
Page 74: ...2 56 www honeywell com Configuring via the Web Server Configuring Users ...
Page 84: ...3 10 www honeywell com Configuring via WIN PAK Adding a New NetAXS Panel ...
Page 86: ...3 12 www honeywell com Configuring via WIN PAK Adding a New NetAXS Panel ...
Page 100: ...4 14 www honeywell com Monitoring NetAXS Status Monitoring System Status ...