Lyric Gateway Installation and Reference Guide
- 19 -
Zone Resp
Zone Resp
Zone Resp
Zone Response Type Definitions
onse Type Definitions
onse Type Definitions
onse Type Definitions (Continued)
Response
Response
Response
Response Type
Type
Type
Type
Function
Function
Function
Function
Characteristics
Characteristics
Characteristics
Characteristics
Fire with
Verification
Can be assigned to any wireless zone used
as a fire zone. Fire with verification is
available with smoke detector device type. It
cannot be used with heat detectors,
combination heat/smoke detectors or fire
pull stations. This zone type is always active
and cannot be bypassed.
•
Alarm sound will pulse (Temporal Fire) when this zone type is
alarmed and the alarm has been verified.
•
System verifies alarm by delaying reporting and alarm
sounding for 30 seconds after alarm is detected. If the zone
remains faulted after 30 seconds a fire alarm is provided. If
any other fire zone is faulted during the 30 second delay
window a fire alarm is immediately provided for that zone.
An alarm for original fire zone will also be provided, if that
zone is still faulted. If there are no fire alarms after the 30
second delay expires, the system will open a 60 second
window. If any fire zone is faulted during that window a fire
alarm will immediately be provided for that zone.
Arm–Stay
Special-purpose zone type used with 5800
and SiX™ Series wireless keys.
•
Exit delay regardless of the arming mode selected.
•
System armed in Home (Stay) mode when zone is activated.
Arm–Away
Special-purpose zone type used with 5800
and SiX™ Series wireless keys.
•
System is armed in the Away mode when the zone is
activated.
Disarm
Special-purpose zone type used with 5800
and SiX™ Series wireless keys.
•
Disarms the system when the zone is activated.
No Response
Assigned when no-alarm response is required.
•
No reports to the Central Station.
•
No keypad sounding or chime and no display on screen.
•
System can still be armed.
Monitor
Can be assigned to any wireless zone used
for asset protection. Works as a dynamic
monitor of a zone fault/trouble (not alarm).
•
Reports to the Central Station, if enabled.
•
Fault/restore events are logged by the system.
•
Restore will be stored in event log.
•
No keypad sounding or chime.
•
System can still be armed.
General Monitor
Assigned sensors or contacts on doors and
windows or asset protection within the
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
•
No reports to the Central Station.
•
Fault/restore events are logged by the system.
•
Monitors entry into a monitored area. Activates a one-time
announcement when faulted.
•
General
Response
Assigned sensors or contacts on doors and
windows or asset protection within the
premises. Used to track activity of the
occupant and alert occupant of the activity
of others.
•
No reports to the Central Station.
•
Fault/restore events are logged by the system.
•
Monitors entry into a monitored area. Activates a zone
announcement when faulted.
•
System re-triggers audible sounding until acknowledged. (Off
sequence or wireless key)
Resident Monitor
Used to monitor a resident in an area
deemed to be dangerous by a caregiver.
•
No reports to the Central Station.
•
Monitors entry into a monitored area. Activates a zone
announcement when faulted.
•
Fault/Restore events are not logged by the system.
Resident
Response
Used to monitor a resident in an area
deemed to be dangerous by a caregiver.
Requires acknowledgement by caregiver.
•
No reports to the Central Station.
•
Monitors entry into a monitored area. Activates a zone
announcement when faulted.
•
System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless key).
•
Fault/Restore events are not logged by the system.
Garage
(Burglary)
Assigned to Automatic Garage Door
applications. Provides a status of the garage
door close/open real time state.
•
Associated With Entry Delay #2 Programmed Time.
•
Exit delays when armed in Away, Home (Stay) or Arm Night
(Stay) mode.
•
No Entry Delay when armed Away or Home (Stay) Instant
modes.
•
System can be armed with zone faulted. When zone is closed
it will be included within protection points. If the point is
subsequently violated, it will initiate an alarm.
Garage Monitor
Assigned to Automatic Garage Door
applications. Provides a status of the garage
door close/open real time state.
•
Can be assigned to any wireless zone used for automatic
“Garage Door” Open/Close status.
•
Will not initiate an alarm condition on the Gateway.
•
When zone is in the open state will display “FAULT.”
•
Does not report alarms to Central Station.
•
Zone chimes, if enabled.
•
System can be armed if this zone type is in fault.
Summary of Contents for Lyric LCP300-LC
Page 42: ...Lyric Gateway Installation and Reference Guide 42 Notes Notes Notes Notes ...
Page 43: ...Lyric Gateway Installation and Reference Guide 43 Notes Notes Notes Notes ...
Page 44: ...Lyric Gateway Installation and Reference Guide 44 Notes Notes Notes Notes ...
Page 45: ...Lyric Gateway Installation and Reference Guide 45 Notes Notes Notes Notes ...