Metering Lines (4)
6 - 7
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
Enter a value in the following range:
4 mA Temp Setting to 20 mA Temp setting
(Only if Temp. Sensor = 4-20 mA)
Or
Min Error Limit to Max Error Limit (Only if Temp. Sensor = RTD)
Meter n
Density correction
Allows enabling or disabling the density correction.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only with volumetric load
Not available for commodity type Special (C)
Select one of the following options:
Enable
Disable*
Meter n
4mA Density
The density that corresponds to a 4 mA reading from the density probe
associated with this metering line.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if density correction is enabled.
Enter a value in the following range:
Refer to Table 6-2.
Meter n 20mA Density
The density that corresponds to a 20 mA reading from the density probe
associated with this metering line.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if density correction is enabled
Table 6-2: Commodity Based Density Range
Units
Base
Temp
Crude
Oils
(A)
Refined
(B)
Special
(C -
thermal
exp.)
Lube
Oils
(D)
NGL and
LPG
(E)
FAME
(F)
Relative
Density
(RD60
60 °F
0.61120 to 1.16464
N/A
0.80168
to 1.1646
0.3500 to
0.6880
N/A
kg/m
3
15 °C
610.6 to 1163.5
N/A
800.9 to
1163.5
351.7 to
687.8
610.6 to
1163.5
20 °C
N/A
331.7 to
683.6
N/A