System (2)
4 - 3
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
4.2 General Setup (21)
The General Setup sub-menu of the System menu covers the selection
of items such as Language Options, Timeouts, Personal, Vehicle
Authorisations and RIT configuration.
4.2.1 Language Options
This Option is not available with the standard CB Application Pack.
Language options not available
4.2.2 Arms
Use the Arms sub-menu to set the first arm number.
First Arm Number
When there are multiple instruments in a single bay, consecutive arm
numbers can be assigned across the units to match the numbering of
the physical loading arms.
Enter a value in the following range:
1 to 6 (1*)
4.2.3 Remote Interaction Terminal (RIT) Panel
Use the RIT to operate the instrument without using the keyboard in
stand- alone mode and in load scheduling mode. After enabling RIT, 3
inputs and 3 outputs must be assigned for each arm. Inputs 11 to 16
and outputs 25 to 30 are assigned to RIT by default. The operator can
select the desired inputs and outputs through the general purpose
inputs and outputs menu.
Use this menu enable or disable the RIT PANEL. When the RIT is
enabled, user can set different states for RIT lamp outputs as below.
Select one of the following options:
Enable
Disable*
GENERAL SETUP 21
- TIMEOUTS
- BAY NUMBER
- DISPLAY CONTRAST
- ARMS
- RIT PANEL
PRESS ENTER TO SELECT
- LANGUAGE OPTIONS
GENERAL SETUP 21
- TIMEOUTS
- BAY NUMBER
- DISPLAY CONTRAST
- ARMS
- RIT PANEL
PRESS ENTER TO SELECT