Metering Lines (4)
6 - 3
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
K-Factor 1 (0 Hz)
Allows entry of up to 5 K-Factors for non-linear flow meters.
Constraints:
Non-linear only.
Enter a value in the following range:
0.001 to 50000.0 (1.0*)
Frequency n (2 - 5)
Sets the next frequency point of the next non-linear K-factor.
Constraints:
Non-linear only.
Enter a value in the following range:
0 to 2000 (1 Hz*)
K-Factor n (2-5)
Sets the K-Factor at the corresponding frequency point.
Constraints:
Non-linear only.
Enter a value in the following range:
Range is displayed on instrument which is ±5% of K-Factor 1
6.2.4 Signal Type
Minimum Linear Flow
rate
The minimum linear flow rate for the flow meter as specified by the flow
meter manufacturer in units/min.
Constraints:
Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
For more information, see chapter 15 “Setting Cut-Off Frequency” in the
1010CB Software Manual.
Constraints:
Dual signal only.
Enter a value in the following range:
0 to X—X calculated by the instrument (200*)
Signal Type Meter n
Selects the flow meter output type. SINGLE has one pulse output and
DUAL has two pulse outputs (sometimes called Quadrature, and used
to monitor signal integrity, but does not detect reverse flow).
Constraints:
Only available when you use the Weights and Measures
switch on the instrument to enter programming mode.
Select one of the following options:
Single*
Dual
Cutoff Meter n
Signal input frequency (Hz) below which the signal integrity of a dual
pulse type flow meter is not monitored.
For more information, see chapter 15 “Setting Cut-Off Frequency” in the
1010CB Software Manual.