background image

Copyright, Notices, Trademarks

This work contains valuable, confidential and proprietary information. Disclosure, use or reproduction outside of BW Technologies by Honeywell (BW Technologies) and/or Honeywell 
International Inc. (Honeywell) is prohibited except as authorized in writing. This unpublished work is protected by the laws of the United States and other countries.
While this information is presented in good faith and believed to be accurate, BW Technologies and/or Honeywell disclaims the implied warranties of merchantability and fitness for a particular 
purpose and makes no express warranties except as may be stated in its written agreement with and for its customers.
In no event is BW Technologies by Honeywell and/or Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are 
subject to change without notice. The Sampler is a trademark(s) of Honeywell International, Inc. Other brand or product names are trademarks of their respective owners.

Signal Words

This document uses the following signal words, as defined by ANSI Z535.4-1998:

International Symbols

n

Approved to both U.S. and Canadian Standards by CSA International

g

European Explosives Protection

Hazardous situation which, if not avoided, 

will 

result in death or serious injury. This symbol identifies the most extreme hazardous situations.

Hazardous situation which, if not avoided, 

could

 result in death or serious injury.

Hazardous situation which, if not avoided, 

may

 result in moderate or minor injury.

Situations which, if not avoided, may result in property damage.

Summary of Contents for D4-PF-1

Page 1: ...User Manual Motorized Sampling Pump 50105442 056 English BW Technologies 2013 All rights reserved The Sampler ...

Page 2: ......

Page 3: ...ivating the Sampler 4 Normal Operation 4 Operating Guidelines 4 Standard Hose Configuration 5 Sample Tube Connections 5 Block the Airflow 5 Deactivating the Sampler 6 Alarms 6 Low Flow Alarm 6 Low Battery Alarm 6 System Fault Alarm 6 Calibration 6 Calibration Pass 6 Calibration Fail 6 Maintenance 7 Replacing the Batteries 7 Replacing a Filter 8 Draining the Water Trap 8 Troubleshooting 9 Replaceme...

Page 4: ......

Page 5: ... the buyer provide proof of purchase such as the original invoice bill of sale or packing slip to establish that the product is within the warranty period THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE BW SH...

Page 6: ...ogies by Honeywell and or Honeywell liable to anyone for any indirect special or consequential damages The information and specifications in this document are subject to change without notice The Sampler is a trademark s of Honeywell International Inc Other brand or product names are trademarks of their respective owners Signal Words This document uses the following signal words as defined by ANSI...

Page 7: ...BW Technologies single and multiple gas detectors An internal motorized pump transports potentially hazardous gases from a sample area to a detector The Sampler is an accessory for a personal safety device It is your responsibility to respond properly to alarm conditions Order Number Description GA SP01 Motorized sampling pump with rigid probe and sample tubing GA SP02 Motorized sampling pump with...

Page 8: ... using the recommended charger only Do not use any other charger Failure to observe this precaution could lead to fire or explosion Do not change or charge batteries in a hazardous location Doing so will impair the intrinsic safety of the unit and may lead to fire or explosion Read and observe all instructions and precautions in the literature provided with the charger Failure to do so may result ...

Page 9: ...ion mode the next time it is activated Calibration Confirm that the Sampler is on Press and hold C for 6 seconds to start calibration The Sampler beeps then deactivates The Sampler enters calibration mode the next time it is activated Airflow To block airflow through the Sampler firmly press the block trigger Note Airflow can also be blocked by tempo rarily kinking the hose or covering the end of ...

Page 10: ...uick reference card User Manual To order replacement parts refer to Replacement Parts and Accessories The Sampler is shipped with the short sample tube installed The Operation section describes how to replace the sample tube To install the batteries refer to Replacing the Batteries Activating the Sampler 1 To activate the Sampler press C 2 All 3 LEDs flash and the audible alarm beeps 4 times When ...

Page 11: ...until firm resistance is felt Block the Airflow Block the airflow to the Sampler to confirm that it is working correctly and there are no leaks in the system There are two ways for you to test the airflow of the Sampler 1 Press and hold the block trigger 2 Kink the sampling or attachment hose If the red FAIL LED blinks and the alarm beeps while the airflow is blocked then the Sampler is operating ...

Page 12: ...ower nears depletion If the battery voltage drops too low the audible alarm beeps once the red FAIL LED lights and the Sampler turns off Refer to Replacing the Batteries System Fault Alarm If the Sampler detects a system fault the red FAIL LED lights and the audible alarm beeps Press Cto clear the alarm The Sampler automatically enters the calibration mode If the Sampler passes calibration it will...

Page 13: ...lled in the Sampler Refer to Specifications for approved batteries Charge batteries using only a recommended charger Do not use any other charger Failure to observe this precaution could lead to fire or explosion Do not change or charge batteries in a hazardous location Doing so will impair the intrinsic safety of the unit and may lead to fire or explosion Deactivate the Sampler before replacing t...

Page 14: ...s firmly seated into the plug and the open end of the filter is facing out 3 Insert the filter plug assembly into the Sampler ensuring the filter enters the gasket filter opening Draining the Water Trap Empty the water trap periodically Pull open the drain plug and shake any water out of the water trap Replace the plug when complete Filter Filter plug Open end of filter Gasket filter opening Filte...

Page 15: ...er automatically turns off Automatic Shutdown feature activated due to weak batteries Replace batteries Sampler turns off with red FAIL LED flashing A blocked state was not triggered during calibration Activate the Sampler During calibration block the airflow of the Sampler when the yellow LED flashes There is water in the water trap Empty the water trap Filter is in backwards Remove the filter pl...

Page 16: ...w battery system fault Typical Battery Life Alkaline NiMH 30 hours at 25 C 77 F Altitude Up to 9843 ft 3000 m Pollution Degree 2 Installation Category I Approved Batteries North America IECEx Model No Description Qty GAMIC V CHRG1 12V vehicle charger and 4 AA NiMH batteries 1 GAMIC C01 K 110 VAC 4 port charger and 4 AA NiMH batteries 1 GAMIC C01 K xx 220 VAC 4 port charger and 4 AA NiMH batteries ...

Page 17: ...NiMH battery charger with country specific mains adapter Charge Time 1 3 hours Approvals Approved by CSA to both U S and Canadian Standards Class I Division 1 Group A B C and D Class I Zone 0 Group IIC IECEx Approval Ex ia IIC Ga IECEx CSA04 0003X ABS Type Approved VA 348 169 X ...

Page 18: ...The Sampler User Manual 12 ...

Page 19: ......

Page 20: ...User Manual Motorized Sampling Pump 50105442 056 Rev 3 English BW Technologies 2013 All rights reserved The Sampler ...

Reviews: