Data Field Programming
4-13
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*95
Ring Count For Downloading
0 = Disable Monitoring Station initiated
downloading
1–14 = number of rings before control
answers incoming call
#+15 = Answering machine/fax defeat
Refer to the chart below and program this field
accordingly.
phone answer/fax
down-
module machine
loading Set
field
∗∗∗∗
95 to…
yes
no
no
1-14 (not 0)
yes
yes
no
higher than number
of rings set on
answer/fax machine
(e.g., if ans/fax
machine is 4 rings,
set this field to 5).
This allows access
via the phone
module if the
answer/fax machine
is turned off.
yes
no
yes
1-14 (not 0)
yes yes yes 15
(bypasses
answer/fax
machine
†
)
no no no 0
no yes no 0
no no yes
1-14
no yes yes
15
† NOTE:
If “15” is entered to bypass an answering
machine and a TeleCommand Phone Module is
included in the system, you should note the
following:
When calling in from an off-premises phone,
the user should make the initial call, allow 1 or
2 rings only, then hang up, then call again.
The phone module will now seize the line,
and 2 long tones sound, followed by the usual
voice prompt for the access code. If this
procedure is not followed, phone module
operation will not be possible.