Mounting and Wiring the Control
2-17
On-Board Triggers
Connect field wiring to the desired trigger pin
on the 8-pin trigger connector centrally located
above the terminal strip.
•
If using a Powerline Interface Modulator and
powerline carrier devices, use the
SA4120XM-1 cable (part of 4120TR Trigger
Cable). See previous
Powerline Carrier
Device
section.
•
If only using the on-board triggers, you can
use a 4-wire cable (N4632-4, supplied with
the control) as shown below.
1
3
4
5
6
7
8
SA412OXM-1
CABLE
8-PIN TRIGGER CONNECTOR
KEY
00-trigcon-003-V1
+12 A
UX.
D
ATA
COM
SYNC
GND (-)
OUTPUT 17
(RED)
OUTPUT 18
(GREEN)
(ORANGE)
(YELLO
W)
(BLUE)
(PURPLE)
(BLA
CK)
Figure 11. On-Board Trigger Connector with
SA4120XM-1 Cable for Use With X10 Powerline
Interface Modulator
4-WIRE
CABLE
00-trigcon-005-V2
+12 A
UX.
GND (-)
OUTPUT 17
OUTPUT 18
(RED)
(YELLO
W)
(BLA
CK)
(GREEN)
1
3
4
5
6
7
8
8-PIN TRIGGER CONNECTOR
KEY
Figure 12. On-Board Trigger Connector with
4-Wire Cable for Trigger Use Only
Notes
•
There are two on-board triggers that can
be used to activate output devices.
•
These outputs are normally high, and go
low upon programmed condition.
•
The outputs can be programmed for
inverted operation (normally low, go high)
using *79 Menu mode.
•
Program these triggers using *80/*81
Menu modes as you would for any other
relay output.
•
When using these outputs, note:
pin 1 = output number 17 (trigger 1):
15 ohms to ground when closed
(output low), open when off
(output high, normal default); can
be used to reset smoke detector
power (must set “output normal
low = yes” in *79 Menu mode, and
set for zone type 54, fire zone
reset, in *80 Menu mode); or can
support 12V relay module
†
that
draws less than 100mA
pin 5 = output number 18 (trigger 2):
15 ohms to ground when closed
(output low); open when off
(output high, normal default); or
can support 12V relay module
that draws less than 20mA.
NOTE:
Do not exceed 120mA combined
current for both triggers. Doing so
can damage PC board components
and will void the system’s
warranty.
† e.g., Altronix AX-RBS in Canada
Summary of Contents for ADEMCO Vista-12C
Page 2: ...Installation and Setup Guide ii ...
Page 8: ...Installation and Setup Guide 1 4 ...
Page 100: ...Installation and Setup Guide 7 4 ...
Page 106: ...Installation and Setup Guide 8 6 ...