4.
INMARSAT
Operational
A.
General
(1) Class 15 Services.
• Standard IP
• Streaming IP
• BGAN IP Voice
• Combinations of the above.
(2) Background, streaming and subscription traffi
c c
lasses are supported.
(3) User is able to set up 1 primary and up to 9 PDP contexts on a connection.
• Primary and secondary connections can be set up via the RESTful interface
• The WebUI can only set up a primary connection
5.
USIM
A.
General
(1) When a user inserts or removes a SIM card, the indoor unit will reset.
(2) The terminal works with an Inmarsat class 15 USIM Aeronautical provided by the Honeywell
service provider and the Honeywell distribution partner.
6.
LED
Indicator
A.
Indications
are
as
listed
below:
(1) No Power – Off
(2) OK – Green
(3) Error - Red
7.
Temperature
Pro
f
i
le
A.
Antenna
(1) The antenna will survive through a temperature range of -55 to 85°C (-67 to 185°F).
(2) The antenna will operate through an environmental temperature range of -40 to 55°C (-40
to 131°F).
B.
Indoor
Unit
(1) The indoor unit will survive through a temperature range of -55 to 85°C (-67 to 185°F).
(2) The Indoor Unit will operate through an environmental temperature range of -40 to 55°C
(-40 to 131°F).
(3) Refer to Table 7 for ground level thermal capabilities. To ensure that the unit can dissipate heat
at an altitude of more than 15000 ft and less than 55000 ft, a minimum of 2 SCFM is required.
Page 3
7
1
8
Feb 2021
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
SMALL SATCOM