3.
Electrical Installation
A.
General
(1)
If there is a common UAV ground, the Indoor Unit should be electrically cross bonded with less
than or equal to 3.0 milliohms direct current (DC) resistance.
(2)
Only 2 cables are required for operation. One to connect the boxes and the other to connect to
the UAV.
B.
Indoor Unit Installation
(1)
General
– The terminal does not require any calibration by the user/installer.
4.
Physical Connectors
A.
RF Cable
(1)
The Honeywell part number 90600596 will be supplied with the terminal.
(2)
The coax cable is able to handle temperatures between -40°C to 55°C (-40°F to 131°F).
(3)
The cable has a fixed loss requirement and should not be substituted or shortened, or the
terminal will not function properly.
Table
5
. Antenna Cable Properties
Part Number
Coax Type
Length
(cm)
Weight (g)
Bending
Radius In-
stallation
(cm)
Bending
Radius
Repeated
(cm)
SMA Torque
(N.m)
TNC Torque
(N.m)
90600596
LMR-
100A-FR
50
36
0.7
2.5
0.8-1.13
0.46-0.69
(4)
The coax cable connector is a male TNC (to the antenna) and male SMA to the indoor unit.
B.
Harness Assembly
(1)
Length and weight of harness assembly is 150 cm and 120 g, respectively.
(2)
Cable has an 8-pin circular, latching male connector at the Indoor Unit end, namely
FGG-1B-308-CLAD76Z (LEMO 1B range, 8-pin plug with collet for max 7.6 mm diameter
cable), with screening braid and drain wire clamped. Refer to Table
and Figure
Page 2
4
1
8
Feb 2021
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
SMALL SATCOM