Galaxy 3 Series Installation Manual
2-9
Stand-by Battery
The Galaxy 3 Series control panels can accommodate up to 2 x 17 Ahr batteries. Ensure that the battery
connector leads on the control panel Powers Supply Unit (PSU) are connected to the correct terminals on the
battery.
CAUTION:
There is a risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Table 2-3. Battery/Control Panel connections
Battery Start-up
The system can be powered up via the
Battery Start-up
jumper if there is no AC power. To do this, short
out the Battery Start-up jumper for the duration of the configuration process only. Never leave the Battery
Start-up connected or else deep discharge of the Stand-by Battery will occur.
On-Board Power Supply Unit
The on-board Power Supply Unit (PSU) supplies and monitors power to the system and peripherals. The
following table shows the fuse name and value in amps.
G3-144/G3-520:
The Galaxy 3 Series control panel contains four fuses. Details are given in the table below.
NOTE:
The G3-48 does not require fuse AUX2.
Table 2-4. On-board PSU Fuses
Power Monitoring Characteristics:
Low battery level: 11.2V
Deep discharge protection: 10.5V
Overvoltage protection: 14.7V
Stand-by Battery
l
e
n
a
P
l
o
r
t
n
o
C
y
r
e
t
t
a
B
T
A
B
-
l
a
n
i
m
r
e
t
e
v
-
T
A
B
+
l
a
n
i
m
r
e
t
e
v
+
FUSE NAME
VALUE (AMPS)
MONITORS
TYPE
AUX1
1.0
RS485 Line 1, RIO 0, Zones 1-8: +12V,
on-board comms
20 mm, anti-surge
AUX2
1.0
RS485 Line 2, RIO 1, zones 1-8 +12V
20 mm, anti-surge
BATT
1.6
Battery
20 mm, anti-surge
BELL
1.0
Outputs RIO 0 1-4, RIO 1 1-4, Horn output 20 mm, anti-surge
G3-48
The PSU total capacity is 1.5A. Internally the PSU
is split in two in order to ensure sufficient current is
always available for stand-by battery recharge.
The PSU capacity is broken down as follows:
•
Battery:
0.75A
•
Control PCB:
0.25A
•
AUX +12V:
0.5A
G3-144/520
The PSU total capacity is 2.5A. Internally the PSU is
split in two in order to ensure sufficient current is al-
ways available for stand-by battery recharge.
The PSU capacity is broken down as follows:
•
Battery:
1.25A
•
Control PCB:
0.25A
•
AUX +12V:
1.00A
The PSU is available for zones/outputs and peripherals.
Summary of Contents for 3-144
Page 1: ...Galaxy 3 48C 3 144 3 144C 3 520 3 520C Installation Manual Honeywell Security ...
Page 2: ......
Page 8: ...1 2 Galaxy 3 Series Installation Manual ...
Page 10: ...1 4 Galaxy 3 Series Installation Manual ...
Page 50: ...Galaxy 3 Series Installation Manual 3 22 ...
Page 66: ...Galaxy 3 Series Installation Manual 5 8 ...
Page 74: ...Galaxy 3 Series Installation Manual A 8 ...
Page 76: ...Galaxy 3 Series Installation Manual B 2 ...
Page 78: ...Galaxy 3 Series Installation Manual C 2 ...
Page 84: ...E 4 Galaxy 3 Series Installation Manual ...
Page 86: ...Galaxy 3 Series Installation Manual F 2 ...
Page 88: ...1 2 Galaxy 3 Series Installation Manual ...