Galaxy 3 Series Installation Manual
A-5
Keypad Group Restriction:
To restrict the operation of the function only to groups that are
common to both the card and the MAX, press the key when assigning groups to the MAX.
This means that when a card with access to groups 1, 2 and 3 activates the MAX card function
on a MAX module assigned to groups 2, 3 and 4, the function only operates on the common
groups (groups 2 and 3).
6.
Exit engineer mode — engineer code +
esc
: the keypad displays the message
1 MOD. ADDED —
esc=CONTINUE
. LED 2 on the MAX reader switches on. Press the
esc
key; the keypad returns to the
unset banner.
If this message is not displayed, the MAX reader is not communicating with the control panel and has not
been configured into the system (LED 2 does not switch on).
NOTES:
1.
The MAX reader
will not
operate until engineer mode is exited and the reader is configured into the
system.
2.
All MAX doors
must
be closed, otherwise engineer mode cannot be exited.
7.
The on-line MAX reader is now configured into the system
Removing a MAX Reader from the System
Stand Alone Mode
The stand-alone MAX reader is not connected to the
AB line
, therefore it can be removed simply by
disconnecting the power to the reader. There is no requirement to access engineer mode.
On-Line Mode
1.
Access engineer mode.
2.
Disconnect the MAX reader (
AB line
and power).
3.
Exit engineer mode.
The message
1 MOD. MISSING — [<],[>] to View
is displayed.
4.
Press the
A
or
B
key.
The message
MAX X — =REMOVE MODULE
is displayed.
5.
Press the
key to acknowledge and accept that the MAX reader has been removed. The keypad
returns to the unset banner.
Programming Instructions for On-Line Readers
Refer to
Section 6: System Operation
, menu option
63 = OPTIONS
for details on programming the
Open Timeout
,
Close Timeout
and
Group
parameters for the MAX reader.
NOTE:
These programming instructions refer only to on-line MAX readers (modules that are
connected to a host Galaxy panel via the RS485 data bus). For details on stand-alone MAX
installation refer to the
MAX Installation and Operations Guide (L120)
.
For details on the programming of the MAX user cards and functions refer to
Section 6: System
Operation
, menu option
42 = CODES
.
Removing MAX Readers
Summary of Contents for 3-144
Page 1: ...Galaxy 3 48C 3 144 3 144C 3 520 3 520C Installation Manual Honeywell Security ...
Page 2: ......
Page 8: ...1 2 Galaxy 3 Series Installation Manual ...
Page 10: ...1 4 Galaxy 3 Series Installation Manual ...
Page 50: ...Galaxy 3 Series Installation Manual 3 22 ...
Page 66: ...Galaxy 3 Series Installation Manual 5 8 ...
Page 74: ...Galaxy 3 Series Installation Manual A 8 ...
Page 76: ...Galaxy 3 Series Installation Manual B 2 ...
Page 78: ...Galaxy 3 Series Installation Manual C 2 ...
Page 84: ...E 4 Galaxy 3 Series Installation Manual ...
Page 86: ...Galaxy 3 Series Installation Manual F 2 ...
Page 88: ...1 2 Galaxy 3 Series Installation Manual ...