Galaxy 3 Series Installation Manual
5-5
Removing MAX
3
Readers
Removing a MAX
3
Reader from the System
On-Line Mode
1.
Access engineer mode.
2.
Disconnect the MAX
3
reader (
AB line
and power).
3.
Exit engineer mode.
4.
The message
1 MOD. MISSING
—
[<],[>] to View
is displayed.
5.
Press the
A
or
B
key.
6.
The message
MAX XX
—
º
=REMOVE MODULE
is displayed.
7.
Press the
º
key to acknowledge and accept that the MAX
3
reader has been removed. The keypad
returns to the unset banner.
Operating Instructions
The MAX
3
must be presented with a valid user card to allow access. Opening the door without presenting a
valid card activates a door forced alarm at the panel; the buzzer sounds and LED 2 flashes until the door is
closed.
Activating the egress switch allows the door to be opened without activating an alarm when no card
has been presented to the MAX
3
.
1. Ensure that LED 3 is on and all other LEDs are off.
2. Swipe the MAX with a standard user or nightlock access user card. LED 3 switches off and LED 2
switches on for the programmed
Open Timeout
.
3. Open the door while the LED 2 is on and access the area.
4. Close the door; LED 2 switches off and LED 3 switches on. The door must be closed within the
programmed
Close Timeout
; if the door remains open longer than this, an alarm is activated.
Card-Held Function
The MAX
3
card can be assigned a single menu option (refer to option
42.1.8 = CODES.User Codes.MAX
Function
). To activate the function assigned to the MAX
3
card, hold the card in front of the reader for three
seconds; all of the LEDs switch on. If a keypad has been assigned to the MAX function then it displays the
details of this option. If no keypad is assigned, pressing a key on any of the keypads assigned to a common
group to the user displays the card-held function.
Card-Held System Setting
If the MAX
3
card is assigned one of the setting options (option 12, 13, 14 & 16 – 19), the card-held func-
tions starts the setting procedure for the groups assigned to the card.
NOTE:
If
Group Restriction
is assigned, then only the groups that are common to both the MAX
3
reader
and the MAX
3
user are set/unset
To unset the system using the MAX
3
, swipe the reader with a valid MAX
3
card. The MAX
3
reader beeps.
All of the groups assigned to the card are instantly unset.
All new MAX
3
readers default to address
7
.
Summary of Contents for 3-144
Page 1: ...Galaxy 3 48C 3 144 3 144C 3 520 3 520C Installation Manual Honeywell Security ...
Page 2: ......
Page 8: ...1 2 Galaxy 3 Series Installation Manual ...
Page 10: ...1 4 Galaxy 3 Series Installation Manual ...
Page 50: ...Galaxy 3 Series Installation Manual 3 22 ...
Page 66: ...Galaxy 3 Series Installation Manual 5 8 ...
Page 74: ...Galaxy 3 Series Installation Manual A 8 ...
Page 76: ...Galaxy 3 Series Installation Manual B 2 ...
Page 78: ...Galaxy 3 Series Installation Manual C 2 ...
Page 84: ...E 4 Galaxy 3 Series Installation Manual ...
Page 86: ...Galaxy 3 Series Installation Manual F 2 ...
Page 88: ...1 2 Galaxy 3 Series Installation Manual ...