1.  Pull wires through wire 

hole. Position wallplate on 

wall, level, and mark hole 

positions.

2.  Drill holes (3/16” for 

drywall, 7/32” for plaster) 

and tap in supplied wall 

anchors.

3.  Pull wire through wallplate, 

position over anchors, then 

insert and tighten mounting 

screws. Check level if 

desired.

1.  Loosen screw terminals, insert wires into terminal block, then re-tighten screws.
2.  Push excess wire back into the wall opening. 
3.  Plug the wall opening with nonflammable insulation to prevent drafts from affecting 

thermostat operation.

Wiring

NOTES
R & Rc terminals (

T87N

)

In single-transformer system, leave metal 

jumper in place between 

R

 & 

Rc

. Remove 

metal jumper if two-transformer system.

Heat pump systems (

T87N

)

If wiring to a heat pump, use a small piece of 
wire (not supplied) to connect terminals 

and 

Y

.

Wire specifications

Use 18-gauge thermostat wire. Shielded 

cable is not required.

Wallplate installation

Terminal Designations—T87N

Heat relay.

Compressor contactor.

Fan relay.

Heat pump changeover valve 
energized in cooling.

Rc 

Cooling power. Connect to secondary 
side of cooling system transformer.

Heating power. Connect to secondary 
side of heating system transformer.

Heat pump changeover valve 
energized in heating.

Terminal Designations—T87K

Heat relay.

Power. Connect to secondary side of 
heating system transformer.

This terminal can be used for some 
3-wire hot-water valve systems (power 
open and close valves).

R

W

Y

Summary of Contents for T87K

Page 1: ...ntact your local waste management authority for instructions regarding recycling and proper disposal CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage Disconnect power before be...

Page 2: ...9 C Operating Relative Humidity 5 to 90 non condensing Electrical Ratings Voltage 20 30 VAC Running current 0 02 1 0A Install the thermostat about 5 feet 1 5 m above the floor in an area with good ai...

Page 3: ...system leave metal jumper in place between R Rc Remove metal jumper if two transformer system Heat pump systems T87N If wiring to a heat pump use a small piece of wire not supplied to connect terminal...

Page 4: ...fan in a call for heat if a fan wire is connected to the G termi nal Align the slots on the base with tabs on the thermostat then push gently until the thermostat snaps into place Fan operation settin...

Page 5: ...MAGE OF ANY KIND IN CLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states...

Page 6: ...ettre l ancien r gulateur aux poubelles Communiquer avec le service local de cueillette des d chets pour obtenir de l information sur le recyclage ou sur la bonne fa on de disposer d un ancien r gulat...

Page 7: ...90 sans condensation Caract ristiques lectriques nominales Tension 20 30 V c a Intensit de fonctionnement 0 02 1 0 A Installer le thermostat environ 1 5 m tre 5 pieds du sol dans un endroit o l air c...

Page 8: ...rs Installations thermopompes T87N En cas de c blage une thermopompe raccorder les bornes W et Y avec un bout de fil non fourni Caract ristiques du fil Utiliser du fil thermostat de calibre 18 Il n es...

Page 9: ...nde de chaleur si un fil du ventilateur est raccord la borne G Montage du thermostat Thermostat Placer les fentes du couvercle vis vis les languettes du thermostat puis pousser douce ment jusqu ce que...

Page 10: ...T PRODUIT Certaines provinces ne permettent pas l exclusion ou la restriction des dommages indirects ou accessoires et par cons quent la pr sente restriction peut ne pas s appliquer CETTE GARANTIE EST...

Page 11: ...s Page 6 Manual de Uso Espa ol P gina 11 Debe instalarlo un t cnico capacitado y con experiencia Lea atentamente estas instrucciones Si las ignora podr a da arse el producto o generarse condiciones de...

Page 12: ...a 48 9 C Humedad relativa de funcionamiento 5 a 90 sin condensaci n Reg menes el ctricos Tensi n De 20 a 30 V CA Corriente De 0 02 1 0 A Aplicaci n del producto Este termostato proporciona un control...

Page 13: ...a trav s de su orificio Posicione en la pared la placa de montaje niv lelo y marque las posiciones de los orificios 2 Taladre orificios en las posiciones marcadas 3 16 para mamposter a en seco 7 32 p...

Page 14: ...cuando hay demanda de calefacci n si hay conectado un cable del ventilador al terminal G Montaje del termostato Termostato Alinee las ranuras de la cubierta con las leng etas del termostato luego emp...

Page 15: ...I RECTA O INDIRECTAMENTE DEL INCUMPLIMIENTO DE LAS GARANT AS EXPRESAS O IMPL CITAS O DE OTRAS FALLAS DE ESTE PRODUCTO Algunos estados no permiten la exclu si n o limitaci n de los da os accidentales o...

Page 16: ...client au 1 800 468 1502 Necesita ayuda Consulte sobre este producto en http honeywellhome com o llamando sin cargo a atenci n al cliente 1 800 468 1502 Please contact your distributor to order replac...

Reviews: