LTEM-P Installation and Setup Guide
24
NOTE
: In order to select email notification (Multi Mode), an account must be
created in AlarmNet 360 and “Remote Access” must be selected.
Multi-Mode (email notification) is intended as a convenience for
the user and does not replace Central Station reporting of critical
events (alarms, troubles, etc.).
Interactive Event Device
Address
•
01-30
The Interactive Event Device address must match the address of a relay module
enabled in the VISTA control panel (although you do not actually connect a
module).
This device address must be unique from the communicator device address and
the Keypad Address used for Remote Access.
It is recommended to assign device address 25.
FIXED SETTINGS
(the following options are factory set and not programmable)
Cell Rollover
•
ON
Cell Rollover is factory-set to ON and cannot be changed.
All messages (including AlarmNet network supervisory messages) are sent over
the cell network in the event of an Internet failure.
Power Save
•
ON
The Power Save feature is factory-set to ON and cannot be changed.
This feature allows the LTEM-P to meet the 24 hour UL battery backup
requirement.
IP Connection
•
Auto Detect
IP Connection is factory-set to Auto-Detect and cannot be changed.
In Auto Detect mode, the device will always try to use IP* to communicate but it
will not generate a Primary Comm Path Failure unless it previously detected the
presence of IP. As soon as the presence of IP is detected, a Primary Comm Path
Restore message is generated and the value of IP Connectivity programming
parameter is changed from “Auto Detect” to “Detected”.
From this point on, the software expects connectivity. The auto detect logic will
resume only when the parameter is changed back to “Auto Detect”.
*
Ethernet or Wi-Fi, depending on option selected in Comm Path choice.
ECP Status Codes
When the communicator is configured for ECP usage, it sends status messages to the control panel
for battery, power, tamper, and network connectivity failures. Some of the control panels (e.g.,
VISTA-10P, VISTA-15P and VISTA-20P Series) display these on the keypad as “LngRng Radio”
followed by a 4-digit code (listed in the table below). In addition, the Contact ID codes (listed in
Appendix B) for these conditions are sent to the central station by the communicator.
Common ECP Keypad Display Status Codes
STATUS CODE
DESCRIPTION
0000
Control panel lost communication with communicator.
0880
Communicator tamper detected (cover removed).
4005
Communicator has lost contact with AlarmNet.
000F
Communicator is not registered; account not activated.
0019
Communicator shutdown.
0400
Communicator power on / reset AND the control panel lost communications with
communicator.
0C80
Communicator power on / reset AND tamper detected.
0C8F
Communicator power on/ reset AND tamper detected AND not registered.
08E0
Communicator tamper detected and communicator battery low.
3000
Primary power loss (will only be displayed in conjunction with another event).
8000
Battery charger failure (will only be displayed in conjunction with another event).
0060
Low battery (will only be displayed in conjunction with another event).