CONTROLS & FEATURES
29
Ground Fault Circuit Interrupter (GFCI)
This generator has two types of Ground Fault Circuit Interrupter (GFCI) systems,
GFCI system
①
and GFCI system
②
.
GFCI SYSTEM
①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A RECEPTACLES)
If there is a ground-fault current from either A, B or C receptacle, it will shut off
the power to receptacles A, B, and C.
If this GFCI system
①
activates, the AC circuit breaker will be switched to OFF
position and it will shut off power to all receptacles, including GFCI system
②
120 V 20 A DUPLEX RECEPTACLES.
GFCI SYSTEM
②
(120V-20A DUPLEX RECEPTACLE)
If there is a ground-fault current from either 120 V 20 A DUPLEX RECEPTACLE,
then the GFCI System
②
will shut off the power to that 120 V 20 A DUPLEX
RECEPTACLE. GFCI system
①
will not be affected.
AC CIRCUIT
BREAKER
RECEPTACLE C
(120 V 30 A)
GFCI SYSTEM
②
(120V-20A DUPLEX RECEPTACLES)
GFCI SYSTEM
①
(120V-30A, 120V/240V-30A, 120V/240 V-37.5 A RECEPTACLES)
RECEPTACLE B
(120/240 V 30 A)
RECEPTACLE A
(120/240 V 37.5 A)