4
**
Multiple units can be installed in parallel flow configuration for higher flow rate applications.
***
The unit cannot be subjected to freezing conditions. Severe damage to the system or your property could occur.
COMPONENT VALIDATIONS:
Component
Country Of Manufacture
Validation
UF Membrane Elements
France
NSF/ANSI Standard 61
Membrane Pressure Vessel
USA
NSF/ANSI Standard 44*
Control Valve
USA
NSF/ANSI Standard 44* & 372
Backwash Pressure Tank
USA
NSF/ANSI Standard 61
Fittings and Piping**
U.K. and Canada
NSF/ANSI Standard 61
*Material & Structural Integrity Requirements
**Quick Installation Kits
OPERATING CONDITIONS
The following list provides guidance on the feed water conditions required for successful
operation of your UF system. Use of this equipment outside of these operating conditions may
adversely affect the performance of your system, may void your warranty, and can result in
membrane clogging, water leaks, and/or property damage.
Water should be pre-treated as necessary to ensure the following conditions are met:
•
Sediment Pre-Filtration:
5 microns or less
•
Chlorine:
1.0 ppm (mg/l) maximum for continuous flow (up to 2,000 ppm for cleaning only)
•
Iron:
less than 0.30 ppm (mg/l)
•
Manganese:
less than 0.05 ppm (mg/l)
•
Silt Density Index:
less than 6.0
•
pH:
3 to 11
Recommended Pre-Filter Options:
• HomePlus WH-20x1 Whole House Filter P Pentek DGD-5005-20 Cartridge
• Pentek PBH-420-1 Bag Filter H Pentek BP-420-5 Bag Filter
• ClearPlus WH1B+-HF high Flow Series 5 Micron Whole House Sediment Filter Package
• Backwashable NextSand Filter
CONFIRM THAT YOUR WATER CONDITIONS MEET THE ABOVE SPECIFICATIONS
BEFORE COMMENCING THE INSTALLATION PROCESS. IF IN DOUBT, CALL YOUR
DEALER FOR ADVICE. INSTALLED UNITS CANNOT BE RETURNED.